TY - JOUR
T1 - Impact of altered loading conditions on ventricular performance in fetuses with congenital cystic adenomatoid malformation and twin-twin transfusion syndrome
AU - Szwast, A.
AU - Tian, Z.
AU - McCann, M.
AU - Donaghue, D.
AU - Bebbington, M.
AU - Johnson, M.
AU - Wilson, R. D.
AU - Rychik, J.
PY - 2007/7
Y1 - 2007/7
N2 - Objectives: In the fetus with a structurally normal heart, two conditions - giant chest mass, such as congenital cystic adenomatoid malformation (CCAM), and twin-twin transfusion syndrome (TTTS) - alter ventricular loading conditions and may result in cardiovascular compromise. The aim of this study was to elucidate the mechanism of cardiovascular dysfunction by comparing geometry-independent, Doppler flow-derived measures of ventricular performance in fetuses with altered loading conditions vs. those in normal fetuses. Methods Doppler flow-derived measures of myocardial performance index (MPI) as described by Tei, ventricular ejection force as described by Isaaz, and combined cardiac output (CCO) were obtained by echocardiography in fetuses with a normal cardiovascular system (n = 76) or CCAM (n = 36) and fetal partners with TTTS (n = 22). Results: In the CCAM group, systolic performance as evidenced by the ejection forces was preserved, right ventricular (RV) MPI was increased and CCO diminished, suggesting diastolic dysfunction and poor filling secondary to cardiac compression and a tamponade effect. In TTTS, recipient twins exhibited greater left ventricular (LV) ejection forces and higher CCO than donor twins, and had abnormal RV and LV MPI, reflecting increased preload, preserved left systolic performance, but diastolic dysfunction. Donor twins had diminished ejection forces and CCO in comparison with normal controls and recipient partners, reflecting hypovolemia. Conclusions: In both CCAM and recipient twins of the TTTS, diastolic dysfunction plays a significant role in the pathophysiology of each disorder and precedes changes in systolic performance. Measures of ventricular performance can help elucidate poorly understood mechanisms of cardiovascular compromise in the developing fetus.
AB - Objectives: In the fetus with a structurally normal heart, two conditions - giant chest mass, such as congenital cystic adenomatoid malformation (CCAM), and twin-twin transfusion syndrome (TTTS) - alter ventricular loading conditions and may result in cardiovascular compromise. The aim of this study was to elucidate the mechanism of cardiovascular dysfunction by comparing geometry-independent, Doppler flow-derived measures of ventricular performance in fetuses with altered loading conditions vs. those in normal fetuses. Methods Doppler flow-derived measures of myocardial performance index (MPI) as described by Tei, ventricular ejection force as described by Isaaz, and combined cardiac output (CCO) were obtained by echocardiography in fetuses with a normal cardiovascular system (n = 76) or CCAM (n = 36) and fetal partners with TTTS (n = 22). Results: In the CCAM group, systolic performance as evidenced by the ejection forces was preserved, right ventricular (RV) MPI was increased and CCO diminished, suggesting diastolic dysfunction and poor filling secondary to cardiac compression and a tamponade effect. In TTTS, recipient twins exhibited greater left ventricular (LV) ejection forces and higher CCO than donor twins, and had abnormal RV and LV MPI, reflecting increased preload, preserved left systolic performance, but diastolic dysfunction. Donor twins had diminished ejection forces and CCO in comparison with normal controls and recipient partners, reflecting hypovolemia. Conclusions: In both CCAM and recipient twins of the TTTS, diastolic dysfunction plays a significant role in the pathophysiology of each disorder and precedes changes in systolic performance. Measures of ventricular performance can help elucidate poorly understood mechanisms of cardiovascular compromise in the developing fetus.
KW - CCAM
KW - Cardiac performance
KW - Fetal Doppler
KW - Fetal heart
KW - TTTS
UR - http://www.scopus.com/inward/record.url?scp=34447530720&partnerID=8YFLogxK
U2 - 10.1002/uog.4032
DO - 10.1002/uog.4032
M3 - Article
C2 - 17533619
AN - SCOPUS:34447530720
SN - 0960-7692
VL - 30
SP - 40
EP - 46
JO - Ultrasound in Obstetrics and Gynecology
JF - Ultrasound in Obstetrics and Gynecology
IS - 1
ER -