TY - JOUR
T1 - Imaging the breast with EIS
T2 - An initial study of exam consistency
AU - Kerner, Todd E.
AU - Hartov, Alex
AU - Soho, Sandra K.
AU - Poplack, Steven P.
AU - Paulsen, Keith D.
PY - 2002
Y1 - 2002
N2 - Use of electrical impedance spectroscopy (EIS) to image the breasts of women with both normal and abnormal conditions requires the ability to deliver a consistent and repeatable exam. To investigate the degree to which our current imaging system can meet this requirement we conducted an initial study of exam consistency. The trial involved the imaging of 25 breasts stratified into four separate substudies with increasing levels of electrode placement uncertainty. The degree of complexity ranged from single-placement single-session imaging to multiple-placement single-session imaging to multiple-placement multiple-session imaging. Both visual analysis and quantitative comparisons using mean squared difference (MSD) measures between pairs of permittivity and conductivity images were performed. A new breast interface with the improved vertical and radial electrode array positioning capability required to complete this study is described. Not surprisingly, the results show a dominant trend of increased image variability with increased electrode placement uncertainty. Importantly, quantitative levels of image consistency are reported through MSD analysis. On average across all frequencies analysed, MSDs for single placements are well below 1%, near 2-3% for repositioned breasts during the same session and approximately 15% for re-examined breasts in multiple sessions conducted overtime. Overall, these results suggest that EIS breast exams are consistent provided the electrode placement is well controlled, typically with better than 1 cm accuracy.
AB - Use of electrical impedance spectroscopy (EIS) to image the breasts of women with both normal and abnormal conditions requires the ability to deliver a consistent and repeatable exam. To investigate the degree to which our current imaging system can meet this requirement we conducted an initial study of exam consistency. The trial involved the imaging of 25 breasts stratified into four separate substudies with increasing levels of electrode placement uncertainty. The degree of complexity ranged from single-placement single-session imaging to multiple-placement single-session imaging to multiple-placement multiple-session imaging. Both visual analysis and quantitative comparisons using mean squared difference (MSD) measures between pairs of permittivity and conductivity images were performed. A new breast interface with the improved vertical and radial electrode array positioning capability required to complete this study is described. Not surprisingly, the results show a dominant trend of increased image variability with increased electrode placement uncertainty. Importantly, quantitative levels of image consistency are reported through MSD analysis. On average across all frequencies analysed, MSDs for single placements are well below 1%, near 2-3% for repositioned breasts during the same session and approximately 15% for re-examined breasts in multiple sessions conducted overtime. Overall, these results suggest that EIS breast exams are consistent provided the electrode placement is well controlled, typically with better than 1 cm accuracy.
KW - Breast imaging
KW - Electrical impedance spectroscopy
KW - Exam consistency
KW - Image reproducibility
UR - http://www.scopus.com/inward/record.url?scp=0036169413&partnerID=8YFLogxK
U2 - 10.1088/0967-3334/23/1/323
DO - 10.1088/0967-3334/23/1/323
M3 - Article
C2 - 11876237
AN - SCOPUS:0036169413
SN - 0967-3334
VL - 23
SP - 221
EP - 236
JO - Physiological Measurement
JF - Physiological Measurement
IS - 1
ER -