TY - JOUR
T1 - Hybrid stage 1 palliation with simultaneous off-pump ventricular assist device placement in neonates with high-risk single ventricle anatomy
T2 - Initial experience
AU - Mavroudis, Constantine D.
AU - O'Connor, Matthew J.
AU - Wittlieb-Weber, Carol
AU - Edelson, Jonathan B.
AU - Edwards, Jonathan J.
AU - Berger, Justin H.
AU - Lin, Kimberly Y.
AU - Rossano, Joseph
AU - Maeda, Katsuhide
N1 - Publisher Copyright:
© 2023 The Author(s)
PY - 2024/4
Y1 - 2024/4
N2 - Background: Infants with single ventricle heart disease and severe atrioventricular valve regurgitation have poor outcomes following conventional staged palliation. As such, ventricular assist device (VAD) placement along with hybrid stage 1 palliation has been proposed as a bridge to heart transplant. We present a novel surgical technique for VAD implantation concurrent with hybrid stage 1 that avoids cardiopulmonary bypass. Methods: We performed a retrospective review of our institutional experience with this novel surgical technique. Results: Three patients (weight, 2.7-3.5 kg; age, 3 to 5 days) underwent hybrid stage 1 with VAD placement, consisting of bilateral 3.5-mm expandable polytetrafluoroethylene (PTFE) pulmonary artery bands, a ductal stent, a 6-mm Berlin Heart outflow cannula onto the main pulmonary trunk with a 10-mm graft, a 6-mm Berlin Heart outflow cannula onto the right atrium, and a 10-mL Berlin Heart pump. In patients with severe aortic arch hypoplasia or coarctation, a 4-mm PTFE graft was sewn from the VAD outflow graft to the innominate artery to protect coronary and cerebral perfusion. Procedures were performed off bypass with minimal blood product use. Patients were extubated on postoperative days 2, 2, and 5. There were no procedural complications. All patients were transferred out of the intensive care unit and demonstrated appropriate weight gain. Anticoagulation strategy was bivalirudin and antiplatelet therapy. The patients underwent transplantation after 149 days, 157 days, and 288 days of support. Conclusions: Off-pump single ventricle VAD placement is technically feasible and can be done at the time of hybrid stage 1 palliation with minimal operative morbidity as a bridge to transplant.
AB - Background: Infants with single ventricle heart disease and severe atrioventricular valve regurgitation have poor outcomes following conventional staged palliation. As such, ventricular assist device (VAD) placement along with hybrid stage 1 palliation has been proposed as a bridge to heart transplant. We present a novel surgical technique for VAD implantation concurrent with hybrid stage 1 that avoids cardiopulmonary bypass. Methods: We performed a retrospective review of our institutional experience with this novel surgical technique. Results: Three patients (weight, 2.7-3.5 kg; age, 3 to 5 days) underwent hybrid stage 1 with VAD placement, consisting of bilateral 3.5-mm expandable polytetrafluoroethylene (PTFE) pulmonary artery bands, a ductal stent, a 6-mm Berlin Heart outflow cannula onto the main pulmonary trunk with a 10-mm graft, a 6-mm Berlin Heart outflow cannula onto the right atrium, and a 10-mL Berlin Heart pump. In patients with severe aortic arch hypoplasia or coarctation, a 4-mm PTFE graft was sewn from the VAD outflow graft to the innominate artery to protect coronary and cerebral perfusion. Procedures were performed off bypass with minimal blood product use. Patients were extubated on postoperative days 2, 2, and 5. There were no procedural complications. All patients were transferred out of the intensive care unit and demonstrated appropriate weight gain. Anticoagulation strategy was bivalirudin and antiplatelet therapy. The patients underwent transplantation after 149 days, 157 days, and 288 days of support. Conclusions: Off-pump single ventricle VAD placement is technically feasible and can be done at the time of hybrid stage 1 palliation with minimal operative morbidity as a bridge to transplant.
KW - bridge to transplant
KW - congenital heart disease
KW - heart failure
KW - hybrid procedure
KW - single ventricle heart disease
KW - staged palliation
KW - ventricular assist device
UR - http://www.scopus.com/inward/record.url?scp=85178331722&partnerID=8YFLogxK
U2 - 10.1016/j.xjtc.2023.10.022
DO - 10.1016/j.xjtc.2023.10.022
M3 - Article
C2 - 38835568
AN - SCOPUS:85178331722
SN - 2666-2507
VL - 24
SP - 164
EP - 168
JO - JTCVS Techniques
JF - JTCVS Techniques
ER -