TY - JOUR
T1 - High-Yielding Radiosynthesis of [68Ga]Ga-PSMA-11 Using a Low-Cost Microfluidic Device
AU - Zhang, Xin
AU - Liu, Fei
AU - Payne, Adria C.
AU - Nickels, Michael L.
AU - Bellan, Leon M.
AU - Manning, H. Charles
N1 - Publisher Copyright:
© 2020, World Molecular Imaging Society.
PY - 2020/10/1
Y1 - 2020/10/1
N2 - Purpose: Current PET radiotracer production models result in facility and operational costs that scale prohibitively with the number of tracers synthesized, particularly those made as a single dose-on-demand. Short of a paradigm shift in the technology and economics of radiotracer production, the impact of PET on precision medicine will be limited. Inexpensive, microfluidic radiochemistry platforms have the potential to significantly reduce costs associated with dose-on-demand production and expand the breadth of PET tracers accessible for molecular imaging. Procedures: To produce a miniaturized dose-on-demand device for [68Ga]Ga-PSMA-11 production, a microfluidic chip was assembled in polydimethylsiloxane (PDMS), combining all components of tracer production in an integrated, compact, and easily utilized platform. On-chip radionuclide concentration, as well as radionuclide and precursor starting material mixing and reaction were incorporated. The radionuclide was sourced from a standard, commercially available 68Ge/68Ga generator. Optimal reaction conditions were determined, which included precursor concentration (5 μg/mL), temperature (95 °C), and reaction time (1 min). Results: The total trapping efficiency of combined on-chip SCX and SAX columns was greater than 70 % and could be accomplished in ~ 12 min. Under optimized conditions, [68Ga]Ga-PSMA-11 could be reliably synthesized starting from a complete generator elution (1100 MBq [29.7 mCi]) in ~ 12 min, with an average radiochemical yield of 70 %, radiochemical purity > 99 %, and specific activity > 740 MBq/μg (20 mCi/μg). Quality control testing demonstrated that tracer produced using this platform met or exceeded all typical FDA requirements for human use. Conclusions: A simple, low-cost, dose-on-demand radiosynthesis strategy, such as the chip presented here, represents an opportunity to reduce the financial barriers associated with PET imaging. While this study focused on a device for [68Ga]Ga-PSMA-11, the technology is also applicable to a wide range of other tracers where low-cost, automated, dose-on-demand production is highly desirable.
AB - Purpose: Current PET radiotracer production models result in facility and operational costs that scale prohibitively with the number of tracers synthesized, particularly those made as a single dose-on-demand. Short of a paradigm shift in the technology and economics of radiotracer production, the impact of PET on precision medicine will be limited. Inexpensive, microfluidic radiochemistry platforms have the potential to significantly reduce costs associated with dose-on-demand production and expand the breadth of PET tracers accessible for molecular imaging. Procedures: To produce a miniaturized dose-on-demand device for [68Ga]Ga-PSMA-11 production, a microfluidic chip was assembled in polydimethylsiloxane (PDMS), combining all components of tracer production in an integrated, compact, and easily utilized platform. On-chip radionuclide concentration, as well as radionuclide and precursor starting material mixing and reaction were incorporated. The radionuclide was sourced from a standard, commercially available 68Ge/68Ga generator. Optimal reaction conditions were determined, which included precursor concentration (5 μg/mL), temperature (95 °C), and reaction time (1 min). Results: The total trapping efficiency of combined on-chip SCX and SAX columns was greater than 70 % and could be accomplished in ~ 12 min. Under optimized conditions, [68Ga]Ga-PSMA-11 could be reliably synthesized starting from a complete generator elution (1100 MBq [29.7 mCi]) in ~ 12 min, with an average radiochemical yield of 70 %, radiochemical purity > 99 %, and specific activity > 740 MBq/μg (20 mCi/μg). Quality control testing demonstrated that tracer produced using this platform met or exceeded all typical FDA requirements for human use. Conclusions: A simple, low-cost, dose-on-demand radiosynthesis strategy, such as the chip presented here, represents an opportunity to reduce the financial barriers associated with PET imaging. While this study focused on a device for [68Ga]Ga-PSMA-11, the technology is also applicable to a wide range of other tracers where low-cost, automated, dose-on-demand production is highly desirable.
KW - Gallium-68
KW - Microfluidics
KW - PET
KW - PSMA
KW - Radiochemistry
KW - Radiosynthesis
UR - http://www.scopus.com/inward/record.url?scp=85087552670&partnerID=8YFLogxK
U2 - 10.1007/s11307-020-01515-7
DO - 10.1007/s11307-020-01515-7
M3 - Article
C2 - 32632739
AN - SCOPUS:85087552670
SN - 1536-1632
VL - 22
SP - 1370
EP - 1379
JO - Molecular Imaging and Biology
JF - Molecular Imaging and Biology
IS - 5
ER -