TY - JOUR
T1 - High b-value diffusion-weighted MRI of normal brain
AU - Burdette, Jonathan H.
AU - Durden, David D.
AU - Elster, Allen D.
AU - Yen, Yi Fen
PY - 2001
Y1 - 2001
N2 - Purpose: As MR scanner hardware has improved, allowing for increased gradient strengths, we are able to generate higher b values for diffusion-weighted (DW) imaging. Our purpose was to evaluate the appearance of the normal brain on DW MR images as the diffusion gradient strength ("b value") is increased from 1,000 to 3,000 s/mm2. Method: Three sets of echo planar images were acquired at 1.5 T in 25 normal subjects (mean age 61 years) using progressively increasing strengths of a diffusion-sensitizing gradient (corresponding to b values of 0, 1,000, and 3,000 s/mm2). All other imaging parameters remained constant. Qualitative assessments of trace images were performed by two neuroradiologists, supplemented by quantitative measures of MR signal and noise in eight different anatomic regions. Results: As gradient strength increased from b = 1,000 to 3,000, both gray and white matter structures diminished in signal as expected based on their relative diffusion coefficients [calculated average apparent diffusion coefficient (ADC) values: gray matter = 8.5 × 10-4 mm2/s, white matter = 7.5 × 10-4 mm2/s]. The signal-to-noise ratios for the b = 1,000 images were approximately 2.2 times higher than for the b = 3,000 images (p < 0.0001). As the strength of the diffusion-sensitizing gradient increased, white matter became progressively hyperintense to gray matter. Relative to the thalamus, for example, the average MR signal intensity of white matter structures increased by an average of 27.5%, with the densely packed white matter tracts (e.g., middle cerebellar peduncle, tegmentum, and internal capsule) increasing the most. Conclusion: Brain DW images obtained at b = 3,000 appear significantly different from those obtained at b = 1,000, reflecting expected loss of signal from all areas of brain in proportion to their ADC values. Consequently, when all other imaging parameters are held constant, b = 3,000 DW images appear significantly noisier than b = 1,000 images, and white matter tracts are significantly more hyperintense than gray matter structures.
AB - Purpose: As MR scanner hardware has improved, allowing for increased gradient strengths, we are able to generate higher b values for diffusion-weighted (DW) imaging. Our purpose was to evaluate the appearance of the normal brain on DW MR images as the diffusion gradient strength ("b value") is increased from 1,000 to 3,000 s/mm2. Method: Three sets of echo planar images were acquired at 1.5 T in 25 normal subjects (mean age 61 years) using progressively increasing strengths of a diffusion-sensitizing gradient (corresponding to b values of 0, 1,000, and 3,000 s/mm2). All other imaging parameters remained constant. Qualitative assessments of trace images were performed by two neuroradiologists, supplemented by quantitative measures of MR signal and noise in eight different anatomic regions. Results: As gradient strength increased from b = 1,000 to 3,000, both gray and white matter structures diminished in signal as expected based on their relative diffusion coefficients [calculated average apparent diffusion coefficient (ADC) values: gray matter = 8.5 × 10-4 mm2/s, white matter = 7.5 × 10-4 mm2/s]. The signal-to-noise ratios for the b = 1,000 images were approximately 2.2 times higher than for the b = 3,000 images (p < 0.0001). As the strength of the diffusion-sensitizing gradient increased, white matter became progressively hyperintense to gray matter. Relative to the thalamus, for example, the average MR signal intensity of white matter structures increased by an average of 27.5%, with the densely packed white matter tracts (e.g., middle cerebellar peduncle, tegmentum, and internal capsule) increasing the most. Conclusion: Brain DW images obtained at b = 3,000 appear significantly different from those obtained at b = 1,000, reflecting expected loss of signal from all areas of brain in proportion to their ADC values. Consequently, when all other imaging parameters are held constant, b = 3,000 DW images appear significantly noisier than b = 1,000 images, and white matter tracts are significantly more hyperintense than gray matter structures.
KW - Brain
KW - Magnetic resonance imaging
KW - Magnetic resonance imaging, techniques
UR - http://www.scopus.com/inward/record.url?scp=0034759883&partnerID=8YFLogxK
U2 - 10.1097/00004728-200107000-00002
DO - 10.1097/00004728-200107000-00002
M3 - Article
C2 - 11473179
AN - SCOPUS:0034759883
SN - 0363-8715
VL - 25
SP - 515
EP - 519
JO - Journal of Computer Assisted Tomography
JF - Journal of Computer Assisted Tomography
IS - 4
ER -