T1 - Glucose measurement of intensive care unit patient plasma samples using a fixed-wavelength mid-infrared spectroscopy system
AU - Krinsley, James
AU - Bochicchio, Kelly
AU - Calentine, Christopher
AU - Bochicchio, Grant
PY - 2012/3
Y1 - 2012/3
N2 - Objective: Glycemic control is a rapidly developing field in intensive care medicine with the aim of reducing mortality, morbidity, and cost. Current intensive care unit (ICU) glucose measurement technologies are susceptible to interference from medications, volume expanders, and other substances present in critically ill patients. We hypothesized that a fixed-wavelength mid-infrared (mid-IR) spectroscopy system would be accurate for measuring glucose levels of ICU patients. Research Design and Methods: This is a prospective investigation of plasma samples from two diferent institutions treating a heterogeneous population of ICU patients. The first 292 samples were collected from 86 patients admitted to Stamford Hospital, and the next 352 samples were collected from 75 patients from three ICUs at the University of Maryland. Plasma samples were measured on a Fourier-transform infrared or a proprietary spectrometer, with a glucose prediction algorithm to correct for spectral interference, which were compared with reference measurements taken using a YSI 2300 glucose analyzer. Results: Glucose values ranged from 24 to 343 mg/dl. Numerous medications and injury/disease states were observed in the patient populations, with metoprolol, fentanyl, and multiple organ failure the most prevalent. Despite these interferents, there was a high correlation (r ≥ 0.94) and low standard error (≤12.8 mg/dl) between the predicted glucose values and those of the YSI 2300 STAT Plus reference instrument in the three studies. A total of 95.1% of the 644 values in the three studies met International Organization for Standardization 15197 criteria. Conclusion: These results suggest that a fixed-wavelength mid-IR spectrometer can measure glucose accurately in the plasma of ICU patients.
AB - Objective: Glycemic control is a rapidly developing field in intensive care medicine with the aim of reducing mortality, morbidity, and cost. Current intensive care unit (ICU) glucose measurement technologies are susceptible to interference from medications, volume expanders, and other substances present in critically ill patients. We hypothesized that a fixed-wavelength mid-infrared (mid-IR) spectroscopy system would be accurate for measuring glucose levels of ICU patients. Research Design and Methods: This is a prospective investigation of plasma samples from two diferent institutions treating a heterogeneous population of ICU patients. The first 292 samples were collected from 86 patients admitted to Stamford Hospital, and the next 352 samples were collected from 75 patients from three ICUs at the University of Maryland. Plasma samples were measured on a Fourier-transform infrared or a proprietary spectrometer, with a glucose prediction algorithm to correct for spectral interference, which were compared with reference measurements taken using a YSI 2300 glucose analyzer. Results: Glucose values ranged from 24 to 343 mg/dl. Numerous medications and injury/disease states were observed in the patient populations, with metoprolol, fentanyl, and multiple organ failure the most prevalent. Despite these interferents, there was a high correlation (r ≥ 0.94) and low standard error (≤12.8 mg/dl) between the predicted glucose values and those of the YSI 2300 STAT Plus reference instrument in the three studies. A total of 95.1% of the 644 values in the three studies met International Organization for Standardization 15197 criteria. Conclusion: These results suggest that a fixed-wavelength mid-IR spectrometer can measure glucose accurately in the plasma of ICU patients.
KW - Continuous glucose monitoring
KW - Intensive care unit
KW - Interference
KW - Spectroscopy
UR - http://www.scopus.com/inward/record.url?scp=84865121695&partnerID=8YFLogxK
U2 - 10.1177/193229681200600212
DO - 10.1177/193229681200600212
M3 - Article
C2 - 22538138
AN - SCOPUS:84865121695
SN - 1932-2968
VL - 6
SP - 294
EP - 301
JO - Journal of Diabetes Science and Technology
JF - Journal of Diabetes Science and Technology
IS - 2
ER -