N2 - Background: Studies comparing carpal tunnel release with ultrasound guidance (CTR-US) to mini-open CTR (mOCTR) are limited. This randomized trial compared the efficacy and safety of these techniques. Methods: In this multicenter randomized trial, patients were randomized (2:1) to unilateral CTR-US or mOCTR. Outcomes included Boston Carpal Tunnel Questionnaire Symptom Severity Scale (BCTQ-SSS) and Functional Status Scale (BCTQ-FSS), numeric pain scale (0-10), EuroQoL-5 Dimension 5-Level (EQ-5D-5L), scar outcomes, and complications over 1 year. Results: Patients received CTR-US (n = 94) via wrist incision (mean 6mm) or mOCTR (n = 28) via palmar incision (mean 22mm). Comparing CTR-US with mOCTR, the mean changes in BCTQ-SSS (−1.8 versus -1.8; P = 0.96), BCTQ-FSS (−1.0 versus −1.0; P = 0.75), numeric pain scale (−3.9 versus −3.8; P = 0.74), and EQ-5D-5L (0.13 versus 0.12; P = 0.79) over 1 year were comparable between groups. Freedom from scar sensitivity or pain favored CTR-US (95% versus 74%; P = 0.005). Complications occurred in 2.1% versus 3.6% of patients (P = 0.55), all within 3 weeks postprocedure. There was one revision surgery in the CTR-US group, and no revisions for persistent or recurrent symptoms in either group. Conclusions: CTR-US and mOCTR demonstrated similar improvement in carpal tunnel syndrome symptoms and quality of life with comparable low complication rates over 1 year of follow-up. CTR-US was performed with a smaller incision and associated with less scar discomfort.
AB - Background: Studies comparing carpal tunnel release with ultrasound guidance (CTR-US) to mini-open CTR (mOCTR) are limited. This randomized trial compared the efficacy and safety of these techniques. Methods: In this multicenter randomized trial, patients were randomized (2:1) to unilateral CTR-US or mOCTR. Outcomes included Boston Carpal Tunnel Questionnaire Symptom Severity Scale (BCTQ-SSS) and Functional Status Scale (BCTQ-FSS), numeric pain scale (0-10), EuroQoL-5 Dimension 5-Level (EQ-5D-5L), scar outcomes, and complications over 1 year. Results: Patients received CTR-US (n = 94) via wrist incision (mean 6mm) or mOCTR (n = 28) via palmar incision (mean 22mm). Comparing CTR-US with mOCTR, the mean changes in BCTQ-SSS (−1.8 versus -1.8; P = 0.96), BCTQ-FSS (−1.0 versus −1.0; P = 0.75), numeric pain scale (−3.9 versus −3.8; P = 0.74), and EQ-5D-5L (0.13 versus 0.12; P = 0.79) over 1 year were comparable between groups. Freedom from scar sensitivity or pain favored CTR-US (95% versus 74%; P = 0.005). Complications occurred in 2.1% versus 3.6% of patients (P = 0.55), all within 3 weeks postprocedure. There was one revision surgery in the CTR-US group, and no revisions for persistent or recurrent symptoms in either group. Conclusions: CTR-US and mOCTR demonstrated similar improvement in carpal tunnel syndrome symptoms and quality of life with comparable low complication rates over 1 year of follow-up. CTR-US was performed with a smaller incision and associated with less scar discomfort.
UR - http://www.scopus.com/inward/record.url?scp=85186642674&partnerID=8YFLogxK
U2 - 10.1097/GOX.0000000000005665
DO - 10.1097/GOX.0000000000005665
M3 - Article
C2 - 38440365
AN - SCOPUS:85186642674
SN - 2169-7574
VL - 12
SP - E5665
JO - Plastic and Reconstructive Surgery - Global Open
JF - Plastic and Reconstructive Surgery - Global Open
IS - 3
ER -