TY - JOUR
T1 - Feasibility study of individualized optimal positioning selection for left-sided whole breast radiotherapy
T2 - DIBH or prone
AU - Lin, Hui
AU - Liu, Tianyu
AU - Shi, Chengyu
AU - Petillion, Saskia
AU - Kindts, Isabelle
AU - Weltens, Caroline
AU - Depuydt, Tom
AU - Song, Yulin
AU - Saleh, Ziad
AU - Xu, Xie George
AU - Tang, Xiaoli
N1 - Publisher Copyright:
© 2018 American Association of Physicists in Medicine.
PY - 2018/3
Y1 - 2018/3
N2 - The deep inspiration breath hold (DIBH) and prone (P) position are two common heart-sparing techniques for external-beam radiation treatment of left-sided breast cancer patients. Clinicians select the position that is deemed to be better for tissue sparing based on their experience. This approach, however, is not always optimum and consistent. In response to this, we develop a quantitative tool that predicts the optimal positioning for the sake of organs at risk (OAR) sparing. Sixteen left-sided breast cancer patients were considered in the study, each received CT scans in the supine free breathing, supine DIBH, and prone positions. Treatment plans were generated for all positions. A patient was classified as DIBH or P using two different criteria: if that position yielded (1) lower heart dose, or (2) lower weighted OAR dose. Ten anatomical features were extracted from each patient's data, followed by the principal component analysis. Sequential forward feature selection was implemented to identify features that give the best classification performance. Nine statistical models were then applied to predict the optimal positioning and were evaluated using stratified k-fold cross-validation, predictive accuracy and receiver operating characteristic (AUROC). For heart toxicity-based classification, the support vector machine with radial basis function kernel yielded the highest accuracy (0.88) and AUROC (0.80). For OAR overall toxicities-based classification, the quadratic discriminant analysis achieved the highest accuracy (0.90) and AUROC (0.84). For heart toxicity-based classification, Breast volume and the distance between Heart and Breast were the most frequently selected features. For OAR overall toxicities-based classification, Heart volume, Breast volume and the distance between ipsilateral lung and breast were frequently selected. Given the patient data considered in this study, the proposed statistical model is feasible to provide predictions for DIBH and prone position selection as well as indicate important clinical features that affect the position selection.
AB - The deep inspiration breath hold (DIBH) and prone (P) position are two common heart-sparing techniques for external-beam radiation treatment of left-sided breast cancer patients. Clinicians select the position that is deemed to be better for tissue sparing based on their experience. This approach, however, is not always optimum and consistent. In response to this, we develop a quantitative tool that predicts the optimal positioning for the sake of organs at risk (OAR) sparing. Sixteen left-sided breast cancer patients were considered in the study, each received CT scans in the supine free breathing, supine DIBH, and prone positions. Treatment plans were generated for all positions. A patient was classified as DIBH or P using two different criteria: if that position yielded (1) lower heart dose, or (2) lower weighted OAR dose. Ten anatomical features were extracted from each patient's data, followed by the principal component analysis. Sequential forward feature selection was implemented to identify features that give the best classification performance. Nine statistical models were then applied to predict the optimal positioning and were evaluated using stratified k-fold cross-validation, predictive accuracy and receiver operating characteristic (AUROC). For heart toxicity-based classification, the support vector machine with radial basis function kernel yielded the highest accuracy (0.88) and AUROC (0.80). For OAR overall toxicities-based classification, the quadratic discriminant analysis achieved the highest accuracy (0.90) and AUROC (0.84). For heart toxicity-based classification, Breast volume and the distance between Heart and Breast were the most frequently selected features. For OAR overall toxicities-based classification, Heart volume, Breast volume and the distance between ipsilateral lung and breast were frequently selected. Given the patient data considered in this study, the proposed statistical model is feasible to provide predictions for DIBH and prone position selection as well as indicate important clinical features that affect the position selection.
KW - Breast cancer
KW - DIBH
KW - Machine learning
KW - OAR sparing
KW - Prone
UR - http://www.scopus.com/inward/record.url?scp=85041893481&partnerID=8YFLogxK
U2 - 10.1002/acm2.12283
DO - 10.1002/acm2.12283
M3 - Article
C2 - 29436168
AN - SCOPUS:85041893481
SN - 1526-9914
VL - 19
SP - 218
EP - 229
JO - Journal of applied clinical medical physics
JF - Journal of applied clinical medical physics
IS - 2
ER -