TY - JOUR
T1 - FAST (fast analytical simulator of tracer)-PET
T2 - an accurate and efficient PET analytical simulation tool
AU - Li, Suya
AU - Hamdi, Mahdjoub
AU - Dutta, Kaushik
AU - Fraum, Tyler J.
AU - Luo, Jingqin
AU - Laforest, Richard
AU - Shoghi, Kooresh I.
N1 - Publisher Copyright:
© 2024 The Author(s). Published on behalf of Institute of Physics and Engineering in Medicine by IOP Publishing Ltd.
PY - 2024/8/21
Y1 - 2024/8/21
N2 - Objective. Simulation of positron emission tomography (PET) images is an essential tool in the development and validation of quantitative imaging workflows and advanced image processing pipelines. Existing Monte Carlo or analytical PET simulators often compromise on either efficiency or accuracy. We aim to develop and validate fast analytical simulator of tracer (FAST)-PET, a novel analytical framework, to simulate PET images accurately and efficiently. Approach. FAST-PET simulates PET images by performing precise forward projection, scatter, and random estimation that match the scanner geometry and statistics. Although the same process should be applicable to other scanner models, we focus on the Siemens Biograph Vision-600 in this work. Calibration and validation of FAST-PET were performed through comparison with an experimental scan of a National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom. Further validation was conducted between FAST-PET and Geant4 Application for Tomographic Emission (GATE) quantitatively in clinical image simulations in terms of intensity-based and texture-based features and task-based tumor segmentation. Main results. According to the NEMA IQ phantom simulation, FAST-PET’s simulated images exhibited partial volume effects and noise levels comparable to experimental images, with a relative bias of the recovery coefficient RC within 10% for all spheres and a coefficient of variation for the background region within 6% across various acquisition times. FAST-PET generated clinical PET images exhibit high quantitative accuracy and texture comparable to GATE (correlation coefficients of all features over 0.95) but with ∼100-fold lower computation time. The tumor segmentation masks comparison between both methods exhibited significant overlap and shape similarity with high concordance CCC > 0.97 across measures. Significance. FAST-PET generated PET images with high quantitative accuracy comparable to GATE, making it ideal for applications requiring extensive PET image simulations such as virtual imaging trials, and the development and validation of image processing pipelines.
AB - Objective. Simulation of positron emission tomography (PET) images is an essential tool in the development and validation of quantitative imaging workflows and advanced image processing pipelines. Existing Monte Carlo or analytical PET simulators often compromise on either efficiency or accuracy. We aim to develop and validate fast analytical simulator of tracer (FAST)-PET, a novel analytical framework, to simulate PET images accurately and efficiently. Approach. FAST-PET simulates PET images by performing precise forward projection, scatter, and random estimation that match the scanner geometry and statistics. Although the same process should be applicable to other scanner models, we focus on the Siemens Biograph Vision-600 in this work. Calibration and validation of FAST-PET were performed through comparison with an experimental scan of a National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom. Further validation was conducted between FAST-PET and Geant4 Application for Tomographic Emission (GATE) quantitatively in clinical image simulations in terms of intensity-based and texture-based features and task-based tumor segmentation. Main results. According to the NEMA IQ phantom simulation, FAST-PET’s simulated images exhibited partial volume effects and noise levels comparable to experimental images, with a relative bias of the recovery coefficient RC within 10% for all spheres and a coefficient of variation for the background region within 6% across various acquisition times. FAST-PET generated clinical PET images exhibit high quantitative accuracy and texture comparable to GATE (correlation coefficients of all features over 0.95) but with ∼100-fold lower computation time. The tumor segmentation masks comparison between both methods exhibited significant overlap and shape similarity with high concordance CCC > 0.97 across measures. Significance. FAST-PET generated PET images with high quantitative accuracy comparable to GATE, making it ideal for applications requiring extensive PET image simulations such as virtual imaging trials, and the development and validation of image processing pipelines.
KW - GATE simulation
KW - analytical simulation
KW - positron emission tomography
UR - http://www.scopus.com/inward/record.url?scp=85200828025&partnerID=8YFLogxK
U2 - 10.1088/1361-6560/ad6743
DO - 10.1088/1361-6560/ad6743
M3 - Article
C2 - 39047765
AN - SCOPUS:85200828025
SN - 0031-9155
VL - 69
JO - Physics in medicine and biology
JF - Physics in medicine and biology
IS - 16
M1 - 165020
ER -