TY - JOUR
T1 - Factors associated with rhythm control treatment decisions in patients with atrial fibrillation—Insights from the NCDR PINNACLE registry
AU - Gehi, Anil K.
AU - Doros, Gheorghe
AU - Glorioso, Thomas J.
AU - Grunwald, Gary K.
AU - Hsu, Jonathan
AU - Song, Yang
AU - Turakhia, Mintu P.
AU - Turchin, Alexander
AU - Virani, Salim S.
AU - Maddox, Thomas M.
N1 - Publisher Copyright:
© 2017 Elsevier Inc.
PY - 2017/5/1
Y1 - 2017/5/1
N2 - Background Decisions to use rhythm control in atrial fibrillation (AF) should generally be dictated by patient factors, such as quality of life, heart failure, and other comorbidities. Whether or not other factors affect decisions about the use of rhythm control, and catheter ablation in particular, is unknown. Methods A cohort of all patients diagnosed with nonvalvular AF were identified from the National Cardiovascular Data Registry's Practice Innovation and Clinical Excellence (PINNACLE) AF registry of US outpatient cardiology practices during the study period from May 1, 2008, to December 31, 2014. Overall and practice-specific rates of rhythm control (cardioversion, antiarrhythmic drug therapy, or catheter ablation) were assessed. We assessed patient and practice factors associated with rhythm control and determined the relative contribution of patient, practice, and unmeasured practice factors with its use. Results Among 511,958 PINNACLE AF patients, 22.3% were treated with rhythm control and 2.9% underwent catheter ablation. Significant practice variation in rhythm control was present (median rate of rhythm control across practices 22.8%, range 0.2%-62.9%). Significant patient factors associated with rhythm control therapy included white (vs nonwhite) race (odds ratio [OR] 2.43, P < .001), private (vs nonprivate) insurance (OR 1.04, P < .001), and whether a patient was seen by an electrophysiologist (OR 1.77, P < .001). In an analysis of the relative contribution of patient, practice, and unmeasured practice factors with rhythm control, the contribution of unmeasured practice factors (95% range OR 0.29-3.44) exceeded that of either patient (95% range OR 0.46-2.30) or practice (95% range OR 0.15-2.77) factors. Conclusions One in 5 AF patients in the PINNACLE registry received rhythm control, and 1 in 50 received catheter ablation, suggesting that rhythm control may be underused. A variety of measured and unmeasured practice factors unrelated to patient characteristics play a disproportionate role in the use of rhythm control treatment decisions. Understanding the drivers of these decisions may identify inappropriate treatment variation and better inform optimal use of these therapies.
AB - Background Decisions to use rhythm control in atrial fibrillation (AF) should generally be dictated by patient factors, such as quality of life, heart failure, and other comorbidities. Whether or not other factors affect decisions about the use of rhythm control, and catheter ablation in particular, is unknown. Methods A cohort of all patients diagnosed with nonvalvular AF were identified from the National Cardiovascular Data Registry's Practice Innovation and Clinical Excellence (PINNACLE) AF registry of US outpatient cardiology practices during the study period from May 1, 2008, to December 31, 2014. Overall and practice-specific rates of rhythm control (cardioversion, antiarrhythmic drug therapy, or catheter ablation) were assessed. We assessed patient and practice factors associated with rhythm control and determined the relative contribution of patient, practice, and unmeasured practice factors with its use. Results Among 511,958 PINNACLE AF patients, 22.3% were treated with rhythm control and 2.9% underwent catheter ablation. Significant practice variation in rhythm control was present (median rate of rhythm control across practices 22.8%, range 0.2%-62.9%). Significant patient factors associated with rhythm control therapy included white (vs nonwhite) race (odds ratio [OR] 2.43, P < .001), private (vs nonprivate) insurance (OR 1.04, P < .001), and whether a patient was seen by an electrophysiologist (OR 1.77, P < .001). In an analysis of the relative contribution of patient, practice, and unmeasured practice factors with rhythm control, the contribution of unmeasured practice factors (95% range OR 0.29-3.44) exceeded that of either patient (95% range OR 0.46-2.30) or practice (95% range OR 0.15-2.77) factors. Conclusions One in 5 AF patients in the PINNACLE registry received rhythm control, and 1 in 50 received catheter ablation, suggesting that rhythm control may be underused. A variety of measured and unmeasured practice factors unrelated to patient characteristics play a disproportionate role in the use of rhythm control treatment decisions. Understanding the drivers of these decisions may identify inappropriate treatment variation and better inform optimal use of these therapies.
UR - http://www.scopus.com/inward/record.url?scp=85015066680&partnerID=8YFLogxK
U2 - 10.1016/j.ahj.2017.02.006
DO - 10.1016/j.ahj.2017.02.006
M3 - Article
C2 - 28454812
AN - SCOPUS:85015066680
SN - 0002-8703
VL - 187
SP - 88
EP - 97
JO - American heart journal
JF - American heart journal