TY - JOUR
T1 - Evaluation of thromboelastography for monitoring recombinant activated factor VII ex vivo in haemophilia A and B patients with inhibitors
T2 - A multicentre trial
AU - Young, Guy
AU - Ebbesen, Liselotte S.
AU - Viuff, Dorthe
AU - Di Paola, Jorge
AU - Konkle, Barbara A.
AU - Negrier, Claude
AU - Pasi, John
AU - Ingerslev, Jørgen
PY - 2008/6
Y1 - 2008/6
N2 - Predicting the clinical effect of bypassing agents such as recombinant activated factor VII in haemophilia patients with inhibitors is hampered by the limited availability of reliable laboratory monitoring tools. This multicentre, open-label trial aimed to explore the dose-response relationship between recombinant activated factor VII concentration and thromboelastography parameters in blood samples from patients with haemophilia A or B with inhibitors in a nonbleeding state. Citrated whole blood samples from 16 patients (≥16 years) with haemophilia A or B were spiked ex vivo with recombinant activated factor VII (1.2, 1.6, 2.0, 2.6, 3.0, 3.5 μg/ml), corresponding approximately to doses of 90-270 μg/kg. Samples were analysed by Thromboelastograph or Rotation Thromboelastography (three United States and three European centres, respectively) within 30 min (final lipidated recombinant tissue factor 1: 17 000; final CaCl2 15 mM). Thromboelastograph/Rotation Thromboelastography parameters showed large intersubject variation in the baseline profiles. There was a clear effect when recombinant activated factor VII was added; however, a clear concentration-response relationship was only detected for one patient. This is likely due to the fact that the curves were not sufficiently abnormal that led to reduced assay sensitivity. Our preliminary results suggest that thromboelastography may potentially be a clinically useful tool for monitoring changing concentrations of recombinant activated factor VII in haemophilia patients, but only when the baseline curve is significantly abnormal. Thus, test conditions may need to be optimized before Thromboelastograph/Rotation Thromboelastography can be utilized for all inhibitor patients.
AB - Predicting the clinical effect of bypassing agents such as recombinant activated factor VII in haemophilia patients with inhibitors is hampered by the limited availability of reliable laboratory monitoring tools. This multicentre, open-label trial aimed to explore the dose-response relationship between recombinant activated factor VII concentration and thromboelastography parameters in blood samples from patients with haemophilia A or B with inhibitors in a nonbleeding state. Citrated whole blood samples from 16 patients (≥16 years) with haemophilia A or B were spiked ex vivo with recombinant activated factor VII (1.2, 1.6, 2.0, 2.6, 3.0, 3.5 μg/ml), corresponding approximately to doses of 90-270 μg/kg. Samples were analysed by Thromboelastograph or Rotation Thromboelastography (three United States and three European centres, respectively) within 30 min (final lipidated recombinant tissue factor 1: 17 000; final CaCl2 15 mM). Thromboelastograph/Rotation Thromboelastography parameters showed large intersubject variation in the baseline profiles. There was a clear effect when recombinant activated factor VII was added; however, a clear concentration-response relationship was only detected for one patient. This is likely due to the fact that the curves were not sufficiently abnormal that led to reduced assay sensitivity. Our preliminary results suggest that thromboelastography may potentially be a clinically useful tool for monitoring changing concentrations of recombinant activated factor VII in haemophilia patients, but only when the baseline curve is significantly abnormal. Thus, test conditions may need to be optimized before Thromboelastograph/Rotation Thromboelastography can be utilized for all inhibitor patients.
KW - Blood coagulation
KW - Haemophilia
KW - Recombinant activated factor VII
KW - Rotation Thromboelastography
KW - Thromboelastograph
KW - Thromboelastography
UR - http://www.scopus.com/inward/record.url?scp=43449092203&partnerID=8YFLogxK
U2 - 10.1097/MBC.0b013e3283001cdc
DO - 10.1097/MBC.0b013e3283001cdc
M3 - Article
C2 - 18469548
AN - SCOPUS:43449092203
SN - 0957-5235
VL - 19
SP - 276
EP - 282
JO - Blood Coagulation and Fibrinolysis
JF - Blood Coagulation and Fibrinolysis
IS - 4
ER -