TY - JOUR
T1 - Evaluation and Utilization of Flow Artifacts at CT
AU - Robb, Caroline L.
AU - Marquis, Kaitlin M.
AU - Steinbrecher, Kacie L.
AU - Hammer, Mark M.
AU - Henry, Travis
AU - Bhalla, Sanjeev
AU - Raptis, Constantine A.
N1 - Publisher Copyright:
© RSNA, 2024.
PY - 2024/5
Y1 - 2024/5
N2 - Flow artifacts are commonly encountered at contrast-enhanced CT and can be difficult to discern from true pathologic conditions. Therefore, radiologists must be comfortable distinguishing flow artifacts from true pathologic conditions. This is of particular importance when evaluating the pulmonary arteries and aorta, as a flow artifact may be mistaken for a pulmonary embolism or dissection flap. Understanding the mechanics of flow artifacts and how these artifacts are created can help radiologists in several ways. First, this knowledge can help radiologists appreciate how the imaging characteristics of flow artifacts differ from true pathologic conditions. This information can also help radiologists better recognize the clinical conditions that predispose patients to flow artifacts, such as pneumonia, chronic lung damage, and altered cardiac output. By understanding when flow artifacts may be confounding the interpretation of an examination, radiologists can then know when to pursue other troubleshooting methods to assist with the diagnosis. In these circumstances, the radiologist can consider several troubleshooting methods, including adjusting the imaging protocols, recommending when additional imaging may be helpful, and suggesting which imaging study would be the most beneficial. Finally, flow artifacts can also be used as a diagnostic tool when evaluating the vascular anatomy, examples of which include the characterization of shunts, venous collaterals, intimomedial flaps, and alternative patterns of blood flow, as seen in extracorporeal membrane oxygenation circuits.
AB - Flow artifacts are commonly encountered at contrast-enhanced CT and can be difficult to discern from true pathologic conditions. Therefore, radiologists must be comfortable distinguishing flow artifacts from true pathologic conditions. This is of particular importance when evaluating the pulmonary arteries and aorta, as a flow artifact may be mistaken for a pulmonary embolism or dissection flap. Understanding the mechanics of flow artifacts and how these artifacts are created can help radiologists in several ways. First, this knowledge can help radiologists appreciate how the imaging characteristics of flow artifacts differ from true pathologic conditions. This information can also help radiologists better recognize the clinical conditions that predispose patients to flow artifacts, such as pneumonia, chronic lung damage, and altered cardiac output. By understanding when flow artifacts may be confounding the interpretation of an examination, radiologists can then know when to pursue other troubleshooting methods to assist with the diagnosis. In these circumstances, the radiologist can consider several troubleshooting methods, including adjusting the imaging protocols, recommending when additional imaging may be helpful, and suggesting which imaging study would be the most beneficial. Finally, flow artifacts can also be used as a diagnostic tool when evaluating the vascular anatomy, examples of which include the characterization of shunts, venous collaterals, intimomedial flaps, and alternative patterns of blood flow, as seen in extracorporeal membrane oxygenation circuits.
UR - http://www.scopus.com/inward/record.url?scp=85191484505&partnerID=8YFLogxK
U2 - 10.1148/rg.230134
DO - 10.1148/rg.230134
M3 - Article
C2 - 38662588
AN - SCOPUS:85191484505
SN - 0271-5333
VL - 44
JO - Radiographics
JF - Radiographics
IS - 5
M1 - e230134
ER -