TY - JOUR
T1 - Endoscopic Reconstruction of the Anterior Skull Base Following Tumor Resection
T2 - Application of a Novel Bioabsorbable Plate
AU - Piscopo, Anthony J.
AU - Dougherty, Mark C.
AU - Woodiwiss, Timothy R.
AU - Ankrah, Nii Kwanchie
AU - Hughes, Tyler
AU - Seaman, Scott C.
AU - Walsh, Jarrett E.
AU - Graham, Scott M.
AU - Greenlee, Jeremy D.W.
N1 - Publisher Copyright:
© 2022 The Authors. The Laryngoscope published by Wiley Periodicals LLC on behalf of The American Laryngological, Rhinological and Otological Society, Inc.
PY - 2023/5
Y1 - 2023/5
N2 - Objective: Endoscopic repair of skull base defects is required following resection of intracranial pathology via the endoscopic endonasal approach (EEA). Many closure techniques have been described, but choosing between techniques remains controversial. We report outcomes of 560 EEA procedures of skull base reconstruction performed on 508 patients over a 15-year-period. Halfway through this period, we adopted the use of a rigid, bioabsorbable extrasellar plate for reconstruction, enabling a comparison between this technique and those used previously. Methods: All patients undergoing EEA from 2005 to 2019 at our institution were retrospectively reviewed. Demographic information, surgical pathology, tumor dimensions and radiographic features, reconstructive technique, and patient-related outcomes were collected and analyzed with univariate and multivariate statistical modeling. Results: Five-hundred sixty procedures were performed on 508 patients. The series complication rate was 8.2%. Overall, cerebrospinal fluid (CSF) leak rate was 5.0% but varied significantly across closure techniques (p < 0.001). Critically, the CSF leak rate in the 272 cases prior to our 2013 adoption of the Resorb-X Plate (RXP) was 8.5%, whereas leak rate in the subsequent 288 cases was 1.7%. RXP was protective against CSF leak (p = 0.001), whereas gross total resection (GTR) correlated with increased leak rate (p = 0.001). Patient BMI was significantly associated with risk of leak (p = 0.047). Other variables did not impact leak risk. Conclusion: Reconstructive technique, extent of resection, and patient BMI significantly contributed to CSF leak rate. GTR was associated with increased leak risk while the RXP was protective. The bioabsorbable RXP is an effective option for rigid skull base repair with comparatively few complications. Level of Evidence: 3 Laryngoscope, 133:1092–1098, 2023.
AB - Objective: Endoscopic repair of skull base defects is required following resection of intracranial pathology via the endoscopic endonasal approach (EEA). Many closure techniques have been described, but choosing between techniques remains controversial. We report outcomes of 560 EEA procedures of skull base reconstruction performed on 508 patients over a 15-year-period. Halfway through this period, we adopted the use of a rigid, bioabsorbable extrasellar plate for reconstruction, enabling a comparison between this technique and those used previously. Methods: All patients undergoing EEA from 2005 to 2019 at our institution were retrospectively reviewed. Demographic information, surgical pathology, tumor dimensions and radiographic features, reconstructive technique, and patient-related outcomes were collected and analyzed with univariate and multivariate statistical modeling. Results: Five-hundred sixty procedures were performed on 508 patients. The series complication rate was 8.2%. Overall, cerebrospinal fluid (CSF) leak rate was 5.0% but varied significantly across closure techniques (p < 0.001). Critically, the CSF leak rate in the 272 cases prior to our 2013 adoption of the Resorb-X Plate (RXP) was 8.5%, whereas leak rate in the subsequent 288 cases was 1.7%. RXP was protective against CSF leak (p = 0.001), whereas gross total resection (GTR) correlated with increased leak rate (p = 0.001). Patient BMI was significantly associated with risk of leak (p = 0.047). Other variables did not impact leak risk. Conclusion: Reconstructive technique, extent of resection, and patient BMI significantly contributed to CSF leak rate. GTR was associated with increased leak risk while the RXP was protective. The bioabsorbable RXP is an effective option for rigid skull base repair with comparatively few complications. Level of Evidence: 3 Laryngoscope, 133:1092–1098, 2023.
KW - CSF leak
KW - endonasal
KW - pituitary
KW - rigid repair
KW - septal flap
UR - https://www.scopus.com/pages/publications/85144091799
U2 - 10.1002/lary.30501
DO - 10.1002/lary.30501
M3 - Article
C2 - 36477852
AN - SCOPUS:85144091799
SN - 0023-852X
VL - 133
SP - 1092
EP - 1098
JO - Laryngoscope
JF - Laryngoscope
IS - 5
ER -