TY - JOUR
T1 - Emergency Airway Management in a Simulation of Highly Contagious Isolated Patients
T2 - Both Isolation Strategy and Device Type Matter
AU - Plazikowski, Eike
AU - Greif, Robert
AU - Marschall, Jonas
AU - Pedersen, Tina H.
AU - Kleine-Brueggeney, Maren
AU - Albrecht, Roland
AU - Theiler, Lorenz
N1 - Publisher Copyright:
© 2018 by The Society for Healthcare Epidemiology of America. All rights reserved.
PY - 2018/2/1
Y1 - 2018/2/1
N2 - OBJECTIVE To compare 6 airway-management devices in 3 isolation scenarios regarding their effect on airway management: portable isolation unit (PIU), personal protective equipment (PPE), and standard protection measures METHODS In total, 30 anesthesiologists working in emergency medical services performed airway management on mannequins in 3 isolation settings using 6 different airway management devices (in random order): (1) standard Macintosh laryngoscope; (2) Airtraq SP-video-laryngoscope; (3) i-gel; (4) LMA-Fastrach; (5) Ambu fiberoptic-aScope; and (6) Melker cricothyrotomy-set. Each was assessed regarding time-to-ventilate (primary outcome) and rating of difficulty handling the device. RESULTS In 86% (standard protection) and 85% (PPE) of attempts, airway management was achieved in <60 seconds, irrespective of the device used. In the PIU setting, only 69% of attempts succeeded within this time frame (P<.05). Median time-to-ventilate was shorter for standard protection (23 seconds) and PPE (25 seconds) compared to the PIU (38 seconds; P<.001). In the PIU setting, the fiberscope took the longest (median, 170 seconds), while i-gel was the quickest (median, 13 seconds). The rating of difficulty (visual analogue scale [VAS], 0-100) differed significantly between the isolation scenarios: Airway management was most difficult with PIU (VAS, 76), followed by PPE (VAS, 35), and standard protection (VAS, 9) (P<.01). CONCLUSION Wearing PPE produced similar times-to-ventilate as standard protection among anesthesiologists, but it was subjectively rated more difficult. The portable isolation unit permitted acceptable times-to-ventilate when excluding fiberscope and cricothyrotomy. Supraglottic airway devices allowed the fastest airway management in all isolation scenarios, thus being highly recommendable if a portable isolation unit is used and emergency airway management becomes necessary.
AB - OBJECTIVE To compare 6 airway-management devices in 3 isolation scenarios regarding their effect on airway management: portable isolation unit (PIU), personal protective equipment (PPE), and standard protection measures METHODS In total, 30 anesthesiologists working in emergency medical services performed airway management on mannequins in 3 isolation settings using 6 different airway management devices (in random order): (1) standard Macintosh laryngoscope; (2) Airtraq SP-video-laryngoscope; (3) i-gel; (4) LMA-Fastrach; (5) Ambu fiberoptic-aScope; and (6) Melker cricothyrotomy-set. Each was assessed regarding time-to-ventilate (primary outcome) and rating of difficulty handling the device. RESULTS In 86% (standard protection) and 85% (PPE) of attempts, airway management was achieved in <60 seconds, irrespective of the device used. In the PIU setting, only 69% of attempts succeeded within this time frame (P<.05). Median time-to-ventilate was shorter for standard protection (23 seconds) and PPE (25 seconds) compared to the PIU (38 seconds; P<.001). In the PIU setting, the fiberscope took the longest (median, 170 seconds), while i-gel was the quickest (median, 13 seconds). The rating of difficulty (visual analogue scale [VAS], 0-100) differed significantly between the isolation scenarios: Airway management was most difficult with PIU (VAS, 76), followed by PPE (VAS, 35), and standard protection (VAS, 9) (P<.01). CONCLUSION Wearing PPE produced similar times-to-ventilate as standard protection among anesthesiologists, but it was subjectively rated more difficult. The portable isolation unit permitted acceptable times-to-ventilate when excluding fiberscope and cricothyrotomy. Supraglottic airway devices allowed the fastest airway management in all isolation scenarios, thus being highly recommendable if a portable isolation unit is used and emergency airway management becomes necessary.
UR - http://www.scopus.com/inward/record.url?scp=85044314596&partnerID=8YFLogxK
U2 - 10.1017/ice.2017.287
DO - 10.1017/ice.2017.287
M3 - Article
C2 - 29417920
AN - SCOPUS:85044314596
SN - 0899-823X
VL - 39
SP - 145
EP - 151
JO - Infection Control and Hospital Epidemiology
JF - Infection Control and Hospital Epidemiology
IS - 2
ER -