T1 - Diagnostic Accuracy of Central Venous Catheter Confirmation by Bedside Ultrasound Versus Chest Radiography in Critically Ill Patients
T2 - A Systematic Review and Meta-Analysis
AU - Ablordeppey, Enyo A.
AU - Drewry, Anne M.
AU - Beyer, Alexander B.
AU - Theodoro, Daniel L.
AU - Fowler, Susan A.
AU - Fuller, Brian M.
AU - Carpenter, Christopher R.
N1 - Publisher Copyright:
Copyright © 2017 by the Society of Critical Care Medicine and Wolters Kluwer Health, Inc. All Rights Reserved.
PY - 2017/4/1
Y1 - 2017/4/1
N2 - Objective: We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared with chest radiography. Data Sources: PubMed, Embase, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov. Study Selection: Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2 × 2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, interrater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Data Extraction: Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Data Synthesis: Fifteen studies with 1,553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 (0.77-0.86) and 0.98 (0.97-0.99), respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 (14.72-65.78) and 0.25 (0.13-0.47). The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Conclusions: Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography.
AB - Objective: We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared with chest radiography. Data Sources: PubMed, Embase, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov. Study Selection: Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2 × 2 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, interrater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position. Data Extraction: Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio. Data Synthesis: Fifteen studies with 1,553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 (0.77-0.86) and 0.98 (0.97-0.99), respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 (14.72-65.78) and 0.25 (0.13-0.47). The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high. Conclusions: Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography.
KW - central catheter
KW - chest radiograph
KW - meta-analysis
KW - systematic review
KW - ultrasonography interventional
UR - http://www.scopus.com/inward/record.url?scp=85002425580&partnerID=8YFLogxK
U2 - 10.1097/CCM.0000000000002188
DO - 10.1097/CCM.0000000000002188
M3 - Review article
C2 - 27922877
AN - SCOPUS:85002425580
SN - 0090-3493
VL - 45
SP - 715
EP - 724
JO - Critical care medicine
JF - Critical care medicine
IS - 4
ER -