TY - JOUR
T1 - Current Practices in Central Venous Catheter Position Confirmation by Point of Care Ultrasound
T2 - A Survey of Early Adopters
AU - Ablordeppey, Enyo A.
AU - Drewry, Anne M.
AU - Theodoro, Daniel L.
AU - Tian, Lin Lin
AU - Fuller, Brian M.
AU - Griffey, Richard T.
PY - 2019/5/1
Y1 - 2019/5/1
N2 - PURPOSE: Although routine chest radiographs (CXR) to verify correct central venous catheter (CVC) position and exclude pneumothorax are commonly performed, emerging evidence suggests that this practice can be replaced by point of care ultrasound (POCUS). POCUS is advantageous over CXR because it avoids radiation while verifying correct placement and lack of pneumothorax without delay. We hypothesize that a knowledge translation gap exists in this area. We aim to describe the current clinical practice regarding POCUS alone for CVC position confirmation and pneumothorax exclusion as compared with chest radiography. METHODS: We used a modified Dillman technique to conduct a brief web-based survey to Critical Care Medicine and Emergency Medicine physicians (targeted group of early adopters) evaluating the current practice related to CVC position confirmation and PTX exclusion via CXR or POCUS. RESULTS: Of 200 post-training clinicians contacted, 136 (68%) responded to the survey. For routine CVC confirmation and PTX evaluation, 50.7% of Critical Care Medicine physicians and 65.4% of Emergency Medicine physicians reported using CXR alone while 49.3% and 33.1% respectively reported using CXR and ultrasound together. Though 84.6% of clinicians use ultrasound for CVC insertion "most of the time" or "always," none use ultrasound alone for CVC position confirmation, and only 1% has used ultrasound alone for PTX exclusion. CONCLUSIONS: Though data support its utility and advantages for POCUS as a sole modality for CVC position confirmation and PTX evaluation, POCUS is rarely used for this indication. We identified several perceived barriers toward widespread utilization suggesting areas for dissemination and implementation strategy development that will benefit patient care practices.
AB - PURPOSE: Although routine chest radiographs (CXR) to verify correct central venous catheter (CVC) position and exclude pneumothorax are commonly performed, emerging evidence suggests that this practice can be replaced by point of care ultrasound (POCUS). POCUS is advantageous over CXR because it avoids radiation while verifying correct placement and lack of pneumothorax without delay. We hypothesize that a knowledge translation gap exists in this area. We aim to describe the current clinical practice regarding POCUS alone for CVC position confirmation and pneumothorax exclusion as compared with chest radiography. METHODS: We used a modified Dillman technique to conduct a brief web-based survey to Critical Care Medicine and Emergency Medicine physicians (targeted group of early adopters) evaluating the current practice related to CVC position confirmation and PTX exclusion via CXR or POCUS. RESULTS: Of 200 post-training clinicians contacted, 136 (68%) responded to the survey. For routine CVC confirmation and PTX evaluation, 50.7% of Critical Care Medicine physicians and 65.4% of Emergency Medicine physicians reported using CXR alone while 49.3% and 33.1% respectively reported using CXR and ultrasound together. Though 84.6% of clinicians use ultrasound for CVC insertion "most of the time" or "always," none use ultrasound alone for CVC position confirmation, and only 1% has used ultrasound alone for PTX exclusion. CONCLUSIONS: Though data support its utility and advantages for POCUS as a sole modality for CVC position confirmation and PTX evaluation, POCUS is rarely used for this indication. We identified several perceived barriers toward widespread utilization suggesting areas for dissemination and implementation strategy development that will benefit patient care practices.
UR - http://www.scopus.com/inward/record.url?scp=85061731690&partnerID=8YFLogxK
U2 - 10.1097/SHK.0000000000001218
DO - 10.1097/SHK.0000000000001218
M3 - Article
C2 - 30052580
AN - SCOPUS:85061731690
VL - 51
SP - 613
EP - 618
JO - Shock
JF - Shock
SN - 1073-2322
IS - 5
ER -