TY - GEN
T1 - Co-registered 3-D ultrasound and photoacoustic imaging using a 1.75D 1280-channel ultrasound system
AU - Guo, Puyun
AU - Gamelin, John
AU - Yan, Shikui
AU - Aguirre, Andres
AU - Zhu, Quing
PY - 2007
Y1 - 2007
N2 - Photoacoustic imaging is a promising non-invasive imaging technology due to its ability to combine the enhanced contrast of optical absorption with the spatial resolution of acoustic imaging. Co-registered three-dimensional (3-D) ultrasound and photoacoustic imaging takes advantage of both modalities to allow visualization of tissue structures within a volume using simultaneous structural and functional information. 1.75D acoustic arrays are well-suited for this application due to their ability to scan in 3-D volumes rapidly and accurately while maintaining a reasonable system complexity and cost. We have designed, fabricated, and tested a 1.75D 1280-ch ultrasound system for co-registered 3-D ultrasound and photoacoustic imaging. The system features a 1.75D 1280-channel ultrasound array with a center frequency of 5MHz and 80% bandwidth. The electronics includes 1280 high-voltage pulsers, 40 32-to-l multiplexers, amplification circuitry, and a 40-channel data acquisition circuit. The system is able to drive the entire array simultaneously, and each array element independently, to scan a 3-D volume within +/- 40 degrees in azimuth direction and +/- 10 degrees in elevation respectively. System performance including axial and lateral resolution has been characterized and compared with simulations. Co-registered 3-D ultrasound and photoacoustic imaging has been successfully performed on phantoms with different geometries and contrast.
AB - Photoacoustic imaging is a promising non-invasive imaging technology due to its ability to combine the enhanced contrast of optical absorption with the spatial resolution of acoustic imaging. Co-registered three-dimensional (3-D) ultrasound and photoacoustic imaging takes advantage of both modalities to allow visualization of tissue structures within a volume using simultaneous structural and functional information. 1.75D acoustic arrays are well-suited for this application due to their ability to scan in 3-D volumes rapidly and accurately while maintaining a reasonable system complexity and cost. We have designed, fabricated, and tested a 1.75D 1280-ch ultrasound system for co-registered 3-D ultrasound and photoacoustic imaging. The system features a 1.75D 1280-channel ultrasound array with a center frequency of 5MHz and 80% bandwidth. The electronics includes 1280 high-voltage pulsers, 40 32-to-l multiplexers, amplification circuitry, and a 40-channel data acquisition circuit. The system is able to drive the entire array simultaneously, and each array element independently, to scan a 3-D volume within +/- 40 degrees in azimuth direction and +/- 10 degrees in elevation respectively. System performance including axial and lateral resolution has been characterized and compared with simulations. Co-registered 3-D ultrasound and photoacoustic imaging has been successfully performed on phantoms with different geometries and contrast.
KW - 3-D ultrasound imaging
KW - Photo-acoustic imaging
UR - https://www.scopus.com/pages/publications/34247508647
U2 - 10.1117/12.706702
DO - 10.1117/12.706702
M3 - Conference contribution
AN - SCOPUS:34247508647
SN - 081946550X
SN - 9780819465504
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Photons Plus Ultrasound
T2 - Photons Plus Ultrasound: Imaging and Sensing 2007: The Eighth Conference on Biomedical Thermoacoustics, Optoacoustics, and Acousto-optics
Y2 - 21 January 2007 through 24 January 2007
ER -