Originally received: October 19, 2000. Accepted: May 17, 2001. Manuscript no. 200515. 1Department of Ophthalmology, University of California-Davis, Sacramento, California. 2 Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, St. Louis, Missouri. Presented in part at the Annual Meeting of the American Academy of Ophthalmology, Dallas, Texas, October 2000. Supported by Grants EY10376 (Dr. Brandt), EY09341 (Dr. Gordon), and EY09307 (Dr. Kass) from the National Eye Institute, National Institutes of Health, Bethesda, MD; by the Office of Research on Minority Health, National Institutes of Health; by Merck Research Laboratories, West Point, PA (Dr. Kass); and by unrestricted grants from Research to Prevent Blindness, Inc., New York, NY (UC Davis and Washington University School of Medicine). Reprint requests to Mae O. Gordon, PhD, Department of Ophthalmology and Visual Sciences, Washington University School of Medicine, 660 South Euclid, Box 8203, St. Louis, MO 63110-1093.
Publisher Copyright:
© 2020
PY - 2020/4
Y1 - 2020/4
N2 - Objective: Central corneal thickness influences intraocular pressure (IOP) measurement. We examined the central corneal thickness of subjects in the Ocular Hypertension Treatment Study (OHTS) and determined if central corneal thickness is related to race. Design: Cross-sectional study. Participants: One thousand three hundred one OHTS subjects with central corneal thickness measurements. Intervention: Central corneal thickness was determined with ultrasonic pachymeters of the same make and model at all clinical sites of the OHTS. Main Outcome Measures: Correlation of mean central corneal thickness with race, baseline IOP, refraction, age, gender, systemic hypertension, and diabetes. Results: Mean central corneal thickness was 573.0 ± 39.0 μm. Twenty-four percent of the OHTS subjects had central corneal thickness > 600 μm. Mean central corneal thickness for African American subjects (555.7 ± 40.0 μm; n = 318) was 23 μm thinner than for white subjects (579.0 ± 37.0 μm; P < 0.0001). Other factors associated with greater mean central corneal thickness were younger age, female gender, and diabetes. Conclusions: OHTS subjects have thicker corneas than the general population. African American subjects have thinner corneas than white subjects in the study. The effect of central corneal thickness may influence the accuracy of applanation tonometry in the diagnosis, screening, and management of patients with glaucoma and ocular hypertension.
AB - Objective: Central corneal thickness influences intraocular pressure (IOP) measurement. We examined the central corneal thickness of subjects in the Ocular Hypertension Treatment Study (OHTS) and determined if central corneal thickness is related to race. Design: Cross-sectional study. Participants: One thousand three hundred one OHTS subjects with central corneal thickness measurements. Intervention: Central corneal thickness was determined with ultrasonic pachymeters of the same make and model at all clinical sites of the OHTS. Main Outcome Measures: Correlation of mean central corneal thickness with race, baseline IOP, refraction, age, gender, systemic hypertension, and diabetes. Results: Mean central corneal thickness was 573.0 ± 39.0 μm. Twenty-four percent of the OHTS subjects had central corneal thickness > 600 μm. Mean central corneal thickness for African American subjects (555.7 ± 40.0 μm; n = 318) was 23 μm thinner than for white subjects (579.0 ± 37.0 μm; P < 0.0001). Other factors associated with greater mean central corneal thickness were younger age, female gender, and diabetes. Conclusions: OHTS subjects have thicker corneas than the general population. African American subjects have thinner corneas than white subjects in the study. The effect of central corneal thickness may influence the accuracy of applanation tonometry in the diagnosis, screening, and management of patients with glaucoma and ocular hypertension.
UR - http://www.scopus.com/inward/record.url?scp=85081327952&partnerID=8YFLogxK
U2 - 10.1016/j.ophtha.2020.01.028
DO - 10.1016/j.ophtha.2020.01.028
M3 - Article
C2 - 32200829
AN - SCOPUS:85081327952
SN - 0161-6420
VL - 127
SP - S72-S81
JO - Ophthalmology
JF - Ophthalmology
IS - 4
ER -