TY - JOUR
T1 - Catalase-containing silica particles as ultrasound-based hydrogen peroxide sensors to determine infected from noninfected fluid collections in humans
AU - Malone, Christopher D.
AU - Fetzer, David T.
AU - Lux, Jacques
AU - Mattrey, Robert F.
N1 - Publisher Copyright:
© American Roentgen Ray Society
PY - 2019
Y1 - 2019
N2 - OBJECTIVE. Hydrogen peroxide (H2O2) plays a key role in neutrophil oxidative defense against infection. Catalase-containing silica nanoshells are nanoparticles that generate O2 microbubbles imaged with ultrasound in the presence of elevated H2O2. We aimed to determine whether ultrasound-detectable O2 microbubbles produced by catalase-containing silica nanoshells can determine whether fluid collections drained from patients are infected. SUBJECTS AND METHODS. During this HIPAA-compliant, institutional review board–approved study, 52 human fluid samples were collected from clinically required image-guided percutaneous drainage procedures. Catalase-containing silica nanoshells were added to the fluid samples during imaging in real time using a Sequoia-512 15L8-S linear transducer (Siemens Healthcare). Production of detectable microbubbles was graded subjectively as negative (noninfected) or positive (infected) with low, moderate, or high confidence by a single observer blinded to all clinical data. The truth standard was microbiology laboratory culture results. Performance characteristics including ROC curves were calculated. RESULTS. Microbubble detection to distinguish infected from noninfected fluids was 84% sensitive and 72% specific and offered negative and positive predictive values of 89% and 64%, respectively. The AUC was 0.79. Six of nine false-positive samples were peritoneal fluid collections that were all collected from patients with decompensated cirrhosis. CONCLUSION. The presence of elevated H2O2 indicated by microbubble formation in the presence of catalase-containing silica nanoshells is sensitive in distinguishing infected from noninfected fluids and offers a relatively high negative predictive value. False-positive cases may result from noninfectious oxidative stress. Catalase-containing silica nanoshells may constitute a novel point-of-care test performed at time of percutaneous drainage, potentially obviating placement of drains into otherwise sterile collections and minimizing risk of secondary infection or other complication.
AB - OBJECTIVE. Hydrogen peroxide (H2O2) plays a key role in neutrophil oxidative defense against infection. Catalase-containing silica nanoshells are nanoparticles that generate O2 microbubbles imaged with ultrasound in the presence of elevated H2O2. We aimed to determine whether ultrasound-detectable O2 microbubbles produced by catalase-containing silica nanoshells can determine whether fluid collections drained from patients are infected. SUBJECTS AND METHODS. During this HIPAA-compliant, institutional review board–approved study, 52 human fluid samples were collected from clinically required image-guided percutaneous drainage procedures. Catalase-containing silica nanoshells were added to the fluid samples during imaging in real time using a Sequoia-512 15L8-S linear transducer (Siemens Healthcare). Production of detectable microbubbles was graded subjectively as negative (noninfected) or positive (infected) with low, moderate, or high confidence by a single observer blinded to all clinical data. The truth standard was microbiology laboratory culture results. Performance characteristics including ROC curves were calculated. RESULTS. Microbubble detection to distinguish infected from noninfected fluids was 84% sensitive and 72% specific and offered negative and positive predictive values of 89% and 64%, respectively. The AUC was 0.79. Six of nine false-positive samples were peritoneal fluid collections that were all collected from patients with decompensated cirrhosis. CONCLUSION. The presence of elevated H2O2 indicated by microbubble formation in the presence of catalase-containing silica nanoshells is sensitive in distinguishing infected from noninfected fluids and offers a relatively high negative predictive value. False-positive cases may result from noninfectious oxidative stress. Catalase-containing silica nanoshells may constitute a novel point-of-care test performed at time of percutaneous drainage, potentially obviating placement of drains into otherwise sterile collections and minimizing risk of secondary infection or other complication.
KW - Abscess drainage
KW - Contrast-enhanced ultrasound
KW - Gastrointestinal imaging
KW - Molecular imaging
KW - Nanoparticles
UR - http://www.scopus.com/inward/record.url?scp=85068640578&partnerID=8YFLogxK
U2 - 10.2214/AJR.18.20779
DO - 10.2214/AJR.18.20779
M3 - Article
C2 - 30860893
AN - SCOPUS:85068640578
SN - 0361-803X
VL - 213
SP - W9-W16
JO - American Journal of Roentgenology
JF - American Journal of Roentgenology
IS - 1
ER -