TY - JOUR
T1 - Calibration of multisite raters for prospective visual reads of amyloid PET scans
AU - for the LEADS Consortium
AU - The PREVENT-AD Research Group
AU - Alzheimer’s Disease Neuroimaging Initiative
AU - Soleimani-Meigooni, David N.
AU - Pezzoli, Stefania
AU - Blazhenets, Ganna
AU - La Joie, Renaud
AU - Lin, Zoe
AU - Soppe, Carol L.
AU - Johnson, Derek R.
AU - Koran, Mary Ellen I.
AU - McConathy, Jonathan E.
AU - Nasrallah, Ilya M.
AU - Ponisio, Maria Rosana
AU - Tanner, Jeremy A.
AU - Villemagne, Victor L.
AU - Windon, Charles C.
AU - Zeineh, Michael
AU - Biber, Sarah
AU - Kukull, Walter A.
AU - O'Connell, Heather
AU - Peterson, Daniel J.
AU - Mormino, Elizabeth C.
AU - Johnson, Sterling C.
AU - Rabinovici, Gil D.
N1 - Publisher Copyright:
© 2025 The Author(s). Alzheimer's & Dementia published by Wiley Periodicals LLC on behalf of Alzheimer's Association.
PY - 2025/10
Y1 - 2025/10
N2 - INTRODUCTION: In multicenter Alzheimer's disease studies, amyloid positron emission tomography (PET) visual reads are typically performed centrally by a few experts. Incorporating a broader reader network enhances scalability and generalizability. METHODS: Ten neuroimaging experts from eight Alzheimer's Disease Research Centers (ADRCs) visually read 180 amyloid PET scans (30 scans and 15 duplicate scans for each of four tracers, imaged across a wide variety of scanners), using preferred reading software without anatomical imaging or quantitation. Scans were classified as elevated or non-elevated per tracer-specific criteria. Inter- and intra-rater agreement was assessed. RESULTS: Inter-rater agreement was substantial (Fleiss’ κ = 0.78), with full consensus on 69% of scans. Inter-rater reliability was substantial to perfect across tracers (Fleiss’ κ = 0.70–0.87). Intra-rater agreement was substantial to perfect (Cohen's κ = 0.79-1). Scans with intermediate (10–40 Centiloid) quantitation had lower reader agreement. DISCUSSION: A multicenter expert network achieved substantial agreement classifying amyloid PET scans. These scans provide a standard for reader training and reliability assurance in future studies. Highlights: Calibration methods ensure reliable amyloid positron emission tomography (PET) visual reads across multiple raters. Substantial agreement is possible across readers using their preferred tools. Agreement is also substantial regardless of the amyloid PET tracer used. Scans with intermediate (10–40 Centiloid) quantitation have lower reader agreement. The calibration set will become a training tool for amyloid PET visual read studies.
AB - INTRODUCTION: In multicenter Alzheimer's disease studies, amyloid positron emission tomography (PET) visual reads are typically performed centrally by a few experts. Incorporating a broader reader network enhances scalability and generalizability. METHODS: Ten neuroimaging experts from eight Alzheimer's Disease Research Centers (ADRCs) visually read 180 amyloid PET scans (30 scans and 15 duplicate scans for each of four tracers, imaged across a wide variety of scanners), using preferred reading software without anatomical imaging or quantitation. Scans were classified as elevated or non-elevated per tracer-specific criteria. Inter- and intra-rater agreement was assessed. RESULTS: Inter-rater agreement was substantial (Fleiss’ κ = 0.78), with full consensus on 69% of scans. Inter-rater reliability was substantial to perfect across tracers (Fleiss’ κ = 0.70–0.87). Intra-rater agreement was substantial to perfect (Cohen's κ = 0.79-1). Scans with intermediate (10–40 Centiloid) quantitation had lower reader agreement. DISCUSSION: A multicenter expert network achieved substantial agreement classifying amyloid PET scans. These scans provide a standard for reader training and reliability assurance in future studies. Highlights: Calibration methods ensure reliable amyloid positron emission tomography (PET) visual reads across multiple raters. Substantial agreement is possible across readers using their preferred tools. Agreement is also substantial regardless of the amyloid PET tracer used. Scans with intermediate (10–40 Centiloid) quantitation have lower reader agreement. The calibration set will become a training tool for amyloid PET visual read studies.
KW - Amyloid positron emission tomography
KW - inter-rater reliability
KW - intra-rater reliability
KW - visual reader calibration
KW - visual reads
UR - https://www.scopus.com/pages/publications/105017638549
U2 - 10.1002/alz.70732
DO - 10.1002/alz.70732
M3 - Article
C2 - 41030129
AN - SCOPUS:105017638549
SN - 1552-5260
VL - 21
JO - Alzheimer's and Dementia
JF - Alzheimer's and Dementia
IS - 10
M1 - e70732
ER -