T2 - Device utilization ratio as a performance measure for urinary catheter harm
AU - Fakih, Mohamad G.
AU - Gould, Carolyn V.
AU - Trautner, Barbara W.
AU - Meddings, Jennifer
AU - Olmsted, Russell N.
AU - Krein, Sarah L.
AU - Saint, Sanjay
N1 - Publisher Copyright:
© 2015 by The Society for Healthcare Epidemiology of America. All rights reserved.
PY - 2015/12/7
Y1 - 2015/12/7
N2 - Catheter-associated urinary tract infection (CAUTI) is considered a reasonably preventable event in the hospital setting, and it has been included in the US Department of Health and Human Services National Action Plan to Prevent Healthcare-Associated Infections. While multiple definitions for measuring CAUTI exist, each has important limitations, and understanding these limitations is important to both clinical practice and policy decisions. The National Healthcare Safety Network (NHSN) surveillance definition, the most frequently used outcome measure for CAUTI prevention efforts, has limited clinical correlation and does not necessarily reflect noninfectious harms related to the catheter. We advocate use of the device utilization ratio (DUR) as an additional performance measure for potential urinary catheter harm. The DUR is patient-centered and objective and is currently captured as part of NHSN reporting. Furthermore, these data are readily obtainable from electronic medical records. The DUR also provides a more direct reflection of improvement efforts focused on reducing inappropriate urinary catheter use.
AB - Catheter-associated urinary tract infection (CAUTI) is considered a reasonably preventable event in the hospital setting, and it has been included in the US Department of Health and Human Services National Action Plan to Prevent Healthcare-Associated Infections. While multiple definitions for measuring CAUTI exist, each has important limitations, and understanding these limitations is important to both clinical practice and policy decisions. The National Healthcare Safety Network (NHSN) surveillance definition, the most frequently used outcome measure for CAUTI prevention efforts, has limited clinical correlation and does not necessarily reflect noninfectious harms related to the catheter. We advocate use of the device utilization ratio (DUR) as an additional performance measure for potential urinary catheter harm. The DUR is patient-centered and objective and is currently captured as part of NHSN reporting. Furthermore, these data are readily obtainable from electronic medical records. The DUR also provides a more direct reflection of improvement efforts focused on reducing inappropriate urinary catheter use.
UR - https://www.scopus.com/pages/publications/84959219445
U2 - 10.1017/ice.2015.287
DO - 10.1017/ice.2015.287
M3 - Review article
C2 - 26894622
AN - SCOPUS:84959219445
SN - 0899-823X
VL - 37
SP - 327
EP - 333
JO - Infection Control and Hospital Epidemiology
JF - Infection Control and Hospital Epidemiology
IS - 3
ER -