Association of intraventricular mechanical dyssynchrony with response to cardiac resynchronization therapy in heart failure patients with a narrow QRS complex

Rutger J. Van Bommel, Hidekazu Tanaka, Victoria Delgado, Matteo Bertini, Carel Jan Willem Borleffs, Nina Ajmone Marsan, Johannes Holzmeister, Frank Ruschitzka, Martin J. Schalij, Jeroen J. Bax, John Gorcsan

Research output: Contribution to journalArticle

33 Scopus citations

Abstract

Aims Current criteria for cardiac resynchronization therapy (CRT) are restricted to patients with a wide QRS complex (>120 ms). Overall, only 30 of heart failure patients demonstrate a wide QRS complex, leaving the majority of heart failure patients without this treatment option. However, patients with a narrow QRS complex exhibit left ventricular (LV) mechanical dyssynchrony, as assessed with echocardiography. To further elucidate the possible beneficial effect of CRT in heart failure patients with a narrow QRS complex, this two-centre, non-randomized observational study focused on different echocardiographic parameters of LV mechanical dyssynchrony reflecting atrioventricular, interventricular and intraventricular dyssynchrony, and the response to CRT in these patients. Methods and results A total of 123 consecutive heart failure patients with a narrow QRS complex (<120 ms) undergoing CRT was included at two centres. Several widely accepted measures of mechanical dyssynchrony were evaluated: LV filling ratio (LVFT/RR), LV pre-ejection time (LPEI), interventricular mechanical dyssynchrony (IVMD), opposing wall delay (OWD), and anteroseptal posterior wall delay with speckle tracking (ASPWD). Response to CRT was defined as a reduction ≥15 in left ventricular end-systolic volume at 6 months follow-up. Measures of dyssynchrony can frequently be observed in patients with a narrow QRS complex. Nonetheless, for LVFT/RR, LPEI, and IVMD, presence of predefined significant dyssynchrony is <20. Significant intraventricular dyssynchrony is more widely observed in these patients. With receiver operator characteristic curve analyses, both OWD and ASPWD demonstrated usefulness in predicting response to CRT in narrow QRS patients with a cut-off value of 75 and 107 ms, respectively. Conclusion Mechanical dyssynchrony can be widely observed in heart failure patients with a narrow QRS complex. In particular, intraventricular measures of mechanical dyssynchrony may be useful in predicting LV reverse remodelling at 6 months follow-up in heart failure patients with a narrow QRS complex, but with more stringent cut-off values than currently used in 'wide' QRS patients.

Original languageEnglish
Pages (from-to)3054-3062
Number of pages9
JournalEuropean heart journal
Volume31
Issue number24
DOIs
StatePublished - Dec 1 2010
Externally publishedYes

Keywords

  • Cardiac resynchronization therapy
  • Echocardiography
  • Narrow QRS

Fingerprint Dive into the research topics of 'Association of intraventricular mechanical dyssynchrony with response to cardiac resynchronization therapy in heart failure patients with a narrow QRS complex'. Together they form a unique fingerprint.

  • Cite this

    Van Bommel, R. J., Tanaka, H., Delgado, V., Bertini, M., Borleffs, C. J. W., Ajmone Marsan, N., Holzmeister, J., Ruschitzka, F., Schalij, M. J., Bax, J. J., & Gorcsan, J. (2010). Association of intraventricular mechanical dyssynchrony with response to cardiac resynchronization therapy in heart failure patients with a narrow QRS complex. European heart journal, 31(24), 3054-3062. https://doi.org/10.1093/eurheartj/ehq334