TY - JOUR
T1 - Association between SARS-CoV-2 Neutralizing Antibodies and Commercial Serological Assays
AU - Tang, Mei San
AU - Case, James Brett
AU - Franks, Caroline E.
AU - Chen, Rita E.
AU - Anderson, Neil W.
AU - Henderson, Jeffrey P.
AU - DIamond, Michael S.
AU - Gronowski, Ann M.
AU - Farnsworth, Christopher W.
N1 - Publisher Copyright:
© 2020 American Association for Clinical Chemistry 2020. All rights reserved. For permissions, please email: [email protected].
PY - 2020/12/1
Y1 - 2020/12/1
N2 - Background: Commercially available SARS-CoV-2 serological assays based on different viral antigens have been approved for the qualitative determination of anti-SARS-CoV-2 antibodies. However, there are limited published data associating the results from commercial assays with neutralizing antibodies. Methods: Sixty-six specimens from 48 patients with PCR-confirmed COVID-19 and a positive result by the Roche Elecsys Anti-SARS-CoV-2, Abbott SARS-CoV-2 IgG, or EUROIMMUN SARS-CoV-2 IgG assays and 5 control specimens were analyzed for the presence of neutralizing antibodies to SARS-CoV-2. Correlation, concordance, positive percent agreement (PPA), and negative percent agreement (NPA) were calculated at several cutoffs. Results were compared in patients categorized by clinical outcomes. Results: The correlation between SARS-CoV-2 neutralizing titer (EC50) and the Roche, Abbott, and EUROIMMUN assays was 0.29, 0.47, and 0.46, respectively. At an EC50 of 1:32, the concordance kappa with Roche was 0.49 (95% CI; 0.23-0.75), with Abbott was 0.52 (0.28-0.77), and with EUROIMMUN was 0.61 (0.4-0.82). At the same neutralizing titer, the PPA and NPA for the Roche was 100% (94-100) and 56% (30-80); Abbott was 96% (88-99) and 69% (44-86); and EUROIMMUN was 91% (80-96) and 81% (57-93) for distinguishing neutralizing antibodies. Patients who were intubated, had cardiac injury, or acute kidney injury from COVID-19 infection had higher neutralizing titers relative to those with mild symptoms. Conclusions: COVID-19 patients generate an antibody response to multiple viral proteins such that the calibrator ratios on the Roche, Abbott, and EUROIMMUN assays are all associated with SARS-CoV-2 neutralization. Nevertheless, commercial serological assays have poor NPA for SARS-CoV-2 neutralization, making them imperfect proxies for neutralization.
AB - Background: Commercially available SARS-CoV-2 serological assays based on different viral antigens have been approved for the qualitative determination of anti-SARS-CoV-2 antibodies. However, there are limited published data associating the results from commercial assays with neutralizing antibodies. Methods: Sixty-six specimens from 48 patients with PCR-confirmed COVID-19 and a positive result by the Roche Elecsys Anti-SARS-CoV-2, Abbott SARS-CoV-2 IgG, or EUROIMMUN SARS-CoV-2 IgG assays and 5 control specimens were analyzed for the presence of neutralizing antibodies to SARS-CoV-2. Correlation, concordance, positive percent agreement (PPA), and negative percent agreement (NPA) were calculated at several cutoffs. Results were compared in patients categorized by clinical outcomes. Results: The correlation between SARS-CoV-2 neutralizing titer (EC50) and the Roche, Abbott, and EUROIMMUN assays was 0.29, 0.47, and 0.46, respectively. At an EC50 of 1:32, the concordance kappa with Roche was 0.49 (95% CI; 0.23-0.75), with Abbott was 0.52 (0.28-0.77), and with EUROIMMUN was 0.61 (0.4-0.82). At the same neutralizing titer, the PPA and NPA for the Roche was 100% (94-100) and 56% (30-80); Abbott was 96% (88-99) and 69% (44-86); and EUROIMMUN was 91% (80-96) and 81% (57-93) for distinguishing neutralizing antibodies. Patients who were intubated, had cardiac injury, or acute kidney injury from COVID-19 infection had higher neutralizing titers relative to those with mild symptoms. Conclusions: COVID-19 patients generate an antibody response to multiple viral proteins such that the calibrator ratios on the Roche, Abbott, and EUROIMMUN assays are all associated with SARS-CoV-2 neutralization. Nevertheless, commercial serological assays have poor NPA for SARS-CoV-2 neutralization, making them imperfect proxies for neutralization.
KW - COVID-19
KW - SARS-CoV-2
KW - Serology
KW - neutralizing antibodies
UR - http://www.scopus.com/inward/record.url?scp=85099979375&partnerID=8YFLogxK
U2 - 10.1093/clinchem/hvaa211
DO - 10.1093/clinchem/hvaa211
M3 - Article
C2 - 32894750
AN - SCOPUS:85099979375
SN - 0009-9147
VL - 66
SP - 1538
EP - 1547
JO - Clinical chemistry
JF - Clinical chemistry
IS - 12
ER -