T1 - Assessment of Apple Watch Series 6 pulse oximetry and electrocardiograms in a pediatric population
AU - Littell, Lauren
AU - Roelle, Lisa
AU - Dalal, Aarti
AU - Van Hare, George F.
AU - Orr, William B.
AU - Miller, Nathan
AU - Avari Silva, Jennifer N.
N1 - Publisher Copyright:
© 2022 Littell et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2022/8/1
Y1 - 2022/8/1
N2 - Background Recent technologic advances have resulted in increased development and utilization of direct-to-consumer cardiac wearable devices with various functionality. This study aimed to assess Apple Watch Series 6 (AW6) pulse oximetry and electrocardiography (ECG) in a cohort of pediatric patients. Methods This single-center, prospective study enrolled pediatric patients ≥ 3kg and having an ECG and/or pulse oximetry (SpO2) as part of their planned evaluation. Exclusion criteria: 1) non-English speaking patients and 2) patients in state custody. Simultaneous tracings were obtained for SpO2 and ECG with concurrent standard pulse oximeter and 12-lead ECG. AW6 automated rhythm interpretations were compared to physician over-read and categorized as accurate, accurate with missed findings, inconclusive (automated interpretation: “inconclusive”), or inaccurate. Results A total of 84 patients were enrolled over a 5-week period. 68 patients (81%) were placed into the SpO2 and ECG arm, with 16 patients (19%) placed into the SpO2 only arm. Pulse oximetry data was successfully collected in 71/84 (85%) patients and ECG data in 61/68 (90%). ΔSpO2 between modalities was 2.0±2.6% (r = 0.76). ΔRR was 43±44msec (r = 0.96), ΔPR 19±23msec (r = 0.79), ΔQRS 12±13msec (r = 0.78), and ΔQT 20±19msec (r = 0.9). The AW6 automated rhythm analysis yielded a 75% specificity and found: 1) 40/61 (65.6%) “accurate”, 2) 6/61 (9.8%) “accurate with missed findings”, 3) 14/61 (23%) “inconclusive”, and 4) 1/61 (1.6%) incorrect.
AB - Background Recent technologic advances have resulted in increased development and utilization of direct-to-consumer cardiac wearable devices with various functionality. This study aimed to assess Apple Watch Series 6 (AW6) pulse oximetry and electrocardiography (ECG) in a cohort of pediatric patients. Methods This single-center, prospective study enrolled pediatric patients ≥ 3kg and having an ECG and/or pulse oximetry (SpO2) as part of their planned evaluation. Exclusion criteria: 1) non-English speaking patients and 2) patients in state custody. Simultaneous tracings were obtained for SpO2 and ECG with concurrent standard pulse oximeter and 12-lead ECG. AW6 automated rhythm interpretations were compared to physician over-read and categorized as accurate, accurate with missed findings, inconclusive (automated interpretation: “inconclusive”), or inaccurate. Results A total of 84 patients were enrolled over a 5-week period. 68 patients (81%) were placed into the SpO2 and ECG arm, with 16 patients (19%) placed into the SpO2 only arm. Pulse oximetry data was successfully collected in 71/84 (85%) patients and ECG data in 61/68 (90%). ΔSpO2 between modalities was 2.0±2.6% (r = 0.76). ΔRR was 43±44msec (r = 0.96), ΔPR 19±23msec (r = 0.79), ΔQRS 12±13msec (r = 0.78), and ΔQT 20±19msec (r = 0.9). The AW6 automated rhythm analysis yielded a 75% specificity and found: 1) 40/61 (65.6%) “accurate”, 2) 6/61 (9.8%) “accurate with missed findings”, 3) 14/61 (23%) “inconclusive”, and 4) 1/61 (1.6%) incorrect.
UR - http://www.scopus.com/inward/record.url?scp=85152766231&partnerID=8YFLogxK
U2 - 10.1371/journal.pdig.0000051
DO - 10.1371/journal.pdig.0000051
M3 - Article
AN - SCOPUS:85152766231
SN - 2767-3170
VL - 1
JO - PLOS Digital Health
JF - PLOS Digital Health
IS - 8
M1 - e0000051
ER -