TY - JOUR
T1 - Arthroplasty options for the young patient
T2 - Oxinium on cross-linked polyethylene
AU - Bourne, Robert B.
AU - Barrack, Robert
AU - Rorabeck, Cecil H.
AU - Salehi, Abraham
AU - Good, Victoria
PY - 2005/12
Y1 - 2005/12
N2 - Our purpose was to determine whether metal femoral heads scratch with in vivo use, to characterize the scratching that occurs, and to determine whether this scratching affected polyethylene wear. Assessment of 133 consecutive retrieved femoral heads showed that metal femoral heads do scratch with in vivo use, that cobalt-chromium femoral heads are more scratch resistant than titanium alloy heads, and that scratching seems to be time dependent. Profilmetry studies showed that all roughness parameters (average roughness, maximum peak to lowest valley distance, mean peak height above the mean surface line, estimate of small peaks above the main plateau of the surface, and estimate of the depth of the valleys below the mean plateau of the surface with the exception of the symmetry of the profile about its mean line) showed increased roughness with time of use. Cobalt-chromium and Oxinium femoral heads were damaged in a dislocation model. Assessment of these femoral heads in a wear simulator revealed that against conventional polyethylene, a damaged Oxinium femoral head had no more wear than a new cobalt-chromium articulation on the same polyethylene (36.5/million cycles versus 38.4 mm/million). Against cross-linked polyethylene, a damaged Oxinium femoral head had minimal wear (1.5 mm cubed per Mc).
AB - Our purpose was to determine whether metal femoral heads scratch with in vivo use, to characterize the scratching that occurs, and to determine whether this scratching affected polyethylene wear. Assessment of 133 consecutive retrieved femoral heads showed that metal femoral heads do scratch with in vivo use, that cobalt-chromium femoral heads are more scratch resistant than titanium alloy heads, and that scratching seems to be time dependent. Profilmetry studies showed that all roughness parameters (average roughness, maximum peak to lowest valley distance, mean peak height above the mean surface line, estimate of small peaks above the main plateau of the surface, and estimate of the depth of the valleys below the mean plateau of the surface with the exception of the symmetry of the profile about its mean line) showed increased roughness with time of use. Cobalt-chromium and Oxinium femoral heads were damaged in a dislocation model. Assessment of these femoral heads in a wear simulator revealed that against conventional polyethylene, a damaged Oxinium femoral head had no more wear than a new cobalt-chromium articulation on the same polyethylene (36.5/million cycles versus 38.4 mm/million). Against cross-linked polyethylene, a damaged Oxinium femoral head had minimal wear (1.5 mm cubed per Mc).
UR - http://www.scopus.com/inward/record.url?scp=33644814678&partnerID=8YFLogxK
U2 - 10.1097/01.blo.0000193813.08458.e2
DO - 10.1097/01.blo.0000193813.08458.e2
M3 - Article
C2 - 16330999
AN - SCOPUS:33644814678
SN - 0009-921X
VL - 441
SP - 159
EP - 167
JO - Clinical orthopaedics and related research
JF - Clinical orthopaedics and related research
ER -