Application of Photon-Derived Worst-Case Robustness Criteria to Proton Therapy Planning

Krishmita Siwakoti, Allison P. Dalton, Jared A. Maas, Andrew M. McDonald, Samuel R. Marcrom, Rex A. Cardan, Joseph Harms, John B. Fiveash, Adam J. Kole

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: Robustness evaluation is critical for proton beam therapy (PBT) planning, but ideal robustness criteria are not clearly defined. Here, we compared robustness of PBT plans to published intensity-modulated radiation therapy (IMRT)-derived clinical target volume (CTV) robustness benchmarks and assessed the dosimetric impact of meeting IMRT-derived benchmarks on adjacent organs at risk. Patients and Methods: Patients receiving PBT to 70 GyE in 28 fractions to the prostate alone from 2021 to 2022 at our institution were evaluated. PBT plan robustness was evaluated in nominal and worst-case data scenarios for CTV V100%, CTV V95%, rectum V70 Gy, and bladder V60 Gy. Clinically delivered (“Clinical”) plans were compared to IMRT-derived worst-case CTV benchmarks. If benchmarks were not met, PBT plans were modified to meet both CTV V100% and V95% goals (“Benchmark” plans). Dosimetric comparisons between Clinical and Benchmark plans used a Wilcoxon signed-rank test with alpha set at 0.05. Results: Among 32 patients, median age and PSA at diagnosis were 71 years and 6.84 ng/mL, respectively. Most patients had favorable-intermediate risk disease (56.3%). Only 31% of clinical PBT met both worst-case CTV V100% > 90% and CTV V95% > 99% IMRT benchmarks. Plan renormalization (16 patients) or reoptimization (6 patients) resulted in all Benchmark plans meeting worst-case CTV thresholds. For Benchmark plans, nominal rectum V70 Gy increased from 0.72 to 0.92 cm3, and nominal bladder V60 Gy increased from 5.9% to 6.0% (P < .05 for each). Overall plan hot spot between Clinical and Benchmark plans increased from 104.5 to 105.5% (P < .05). Conclusion: When compared to an IMRT-derived benchmark for robustness coverage, Clinical PBT plans were less robust. However, all PBT plans were successfully modified to meet worst-case CTV benchmark with limited clinically expected impact on organ at risk dosimetry. Consideration should be made to adopt these benchmark criteria for prostate PBT.

Original languageEnglish
Article number100740
JournalInternational Journal of Particle Therapy
Volume15
DOIs
StatePublished - Mar 2025

Keywords

  • Proton therapy
  • Robustness
  • Uncertainty

Fingerprint

Dive into the research topics of 'Application of Photon-Derived Worst-Case Robustness Criteria to Proton Therapy Planning'. Together they form a unique fingerprint.

Cite this