T1 - Anterior and Posterior Fusion for Large, Rigid Idiopathic Scoliosis
T2 - Does Implant Density Matter?
AU - Delman, Connor
AU - Cage, J. Matthew
AU - Lausé, Greg
AU - Roberto, Rolando
AU - Gupta, Munish C.
AU - Klineberg, Eric
N1 - Publisher Copyright:
© 2019
PY - 2020/2
Y1 - 2020/2
N2 - Background: Despite advancements in surgical techniques, controversy remains regarding the optimal implant density for the correction of idiopathic scoliosis. Recent evidence has suggested that equivalent radiographic and clinical outcomes can be achieved with lower implant densities for those with moderate curves and good flexibility. Among the experts, the consensus has continued that higher implant densities should be used for larger, stiffer curves. The purpose of the present study was to compare the radiographic results between high-implant density (HID) and low-implant density (LID) constructs in patients with large (>65°), rigid (<50% flexibility) curves who had undergone anterior release and posterior spinal fusion. Methods: We reviewed the idiopathic scoliosis cases performed at a single institution from 2006 to 2014. Only those meeting the inclusion criteria were selected. The patients were divided into HID and LID groups. The postoperative radiographs were compared for coronal correction, thoracic kyphosis, pelvic tilt, lumbar lordosis, and sagittal vertical axis. Results: A statistically significant improvement in coronal correction was detected in the HID group at all follow-up points (final follow-up: HID, 81.1% vs. LID, 70.4%; P = 0.01). When preoperative thoracic kyphosis was considered, no differences were found between the 2 groups. No differences were found in the other sagittal parameters. Conclusion: In patients with large, rigid idiopathic scoliosis undergoing anterior release and posterior spinal fusion, a small, but statistically, significant improvement in the coronal Cobb angle was seen. It remains to be determined whether this small difference in radiographic correction will have any influence on the clinical outcome.
AB - Background: Despite advancements in surgical techniques, controversy remains regarding the optimal implant density for the correction of idiopathic scoliosis. Recent evidence has suggested that equivalent radiographic and clinical outcomes can be achieved with lower implant densities for those with moderate curves and good flexibility. Among the experts, the consensus has continued that higher implant densities should be used for larger, stiffer curves. The purpose of the present study was to compare the radiographic results between high-implant density (HID) and low-implant density (LID) constructs in patients with large (>65°), rigid (<50% flexibility) curves who had undergone anterior release and posterior spinal fusion. Methods: We reviewed the idiopathic scoliosis cases performed at a single institution from 2006 to 2014. Only those meeting the inclusion criteria were selected. The patients were divided into HID and LID groups. The postoperative radiographs were compared for coronal correction, thoracic kyphosis, pelvic tilt, lumbar lordosis, and sagittal vertical axis. Results: A statistically significant improvement in coronal correction was detected in the HID group at all follow-up points (final follow-up: HID, 81.1% vs. LID, 70.4%; P = 0.01). When preoperative thoracic kyphosis was considered, no differences were found between the 2 groups. No differences were found in the other sagittal parameters. Conclusion: In patients with large, rigid idiopathic scoliosis undergoing anterior release and posterior spinal fusion, a small, but statistically, significant improvement in the coronal Cobb angle was seen. It remains to be determined whether this small difference in radiographic correction will have any influence on the clinical outcome.
KW - Anchor density
KW - Anterior release
KW - Curves
KW - Idiopathic scoliosis
KW - Implant density
KW - Rigid
UR - http://www.scopus.com/inward/record.url?scp=85075430674&partnerID=8YFLogxK
U2 - 10.1016/j.wneu.2019.08.123
DO - 10.1016/j.wneu.2019.08.123
M3 - Article
C2 - 31470168
AN - SCOPUS:85075430674
SN - 1878-8750
VL - 134
SP - e37-e45
JO - World neurosurgery
JF - World neurosurgery