Analysis of prostate patient setup and tracking data: Potential intervention strategies

Zhong Su, Lisha Zhang, Martin Murphy, Jeffrey Williamson

Research output: Contribution to journalArticlepeer-review

27 Scopus citations

Abstract

Purpose: To evaluate the setup, interfraction, and intrafraction organ motion error distributions and simulate intrafraction intervention strategies for prostate radiotherapy. Methods and Materials: A total of 17 patients underwent treatment setup and were monitored using the Calypso system during radiotherapy. On average, the prostate tracking measurements were performed for 8 min/fraction for 28 fractions for each patient. For both patient couch shift data and intrafraction organ motion data, the systematic and random errors were obtained from the patient population. The planning target volume margins were calculated using the van Herk formula. Two intervention strategies were simulated using the tracking data: the deviation threshold and period. The related planning target volume margins, time costs, and prostate position "fluctuation" were presented. Results: The required treatment margin for the left-right, superoinferior, and anteroposterior axes was 8.4, 10.8, and 14.7 mm for skin mark-only setup and 1.3, 2.3, and 2.8 mm using the on-line setup correction, respectively. Prostate motion significantly correlated among the superoinferior and anteroposterior directions. Of the 17 patients, 14 had prostate motion within 5 mm of the initial setup position for ≥91.6% of the total tracking time. The treatment margin decreased to 1.1, 1.8, and 2.3 mm with a 3-mm threshold correction and to 0.5, 1.0, and 1.5 mm with an every-2-min correction in the left-right, superoinferior, and anteroposterior directions, respectively. The periodic corrections significantly increase the treatment time and increased the number of instances when the setup correction was made during transient excursions. Conclusions: The residual systematic and random error due to intrafraction prostate motion is small after on-line setup correction. Threshold-based and time-based intervention strategies both reduced the planning target volume margins. The time-based strategies increased the treatment time and the in-fraction position fluctuation.

Original languageEnglish
Pages (from-to)880-887
Number of pages8
JournalInternational Journal of Radiation Oncology Biology Physics
Volume81
Issue number3
DOIs
StatePublished - Nov 1 2011

Keywords

  • Intervention strategies
  • Intrafraction motion
  • PTV margin
  • Patient setup
  • Planning target volume
  • Tracking

Fingerprint

Dive into the research topics of 'Analysis of prostate patient setup and tracking data: Potential intervention strategies'. Together they form a unique fingerprint.

Cite this