Alterations of coronary collateral blood flow velocity during intraaortic balloon pumping

Michael S. Flynn, Morton J. Kern, Thomas J. Donohue, Frank V. Aguirre, Richard G. Bach, Eugene A. Caracciolo

Research output: Contribution to journalArticlepeer-review

28 Scopus citations

Abstract

Controversy exists regarding the ability of intraaortic balloon pumping to increase coronary blood flow either directly or through collateral perfusion.1-4 In patients, directly measured coronary flow velocity by intracoronary Doppler guidewire technique distal to severe coronary stenoses is minimal and unaffected by intraaortic balloon pumping.5 After coronary angioplasty, intraaortic balloon pumping increases both proximal and, more importantly, distal coronary artery flow velocity.5 Whether collateral flow is altered during intraaortic balloon pumping has not been adequately studied in humans because of a lack of quantitative means to assess collateral blood flow.6 With the use of a Doppler-tipped angioplasty guidewire, retrograde collateral flow velocity can be directly measured, and thus quantitate the effects of interventions altering collateral blood flow responses. 7 While performing angioplasty with the Doppler guidewire, we quantitated intracoronary collateral blood flow alterations during intraaortic balloon pumping in 3 patients: 2 with acute myocardial infarction and 1 with unstable angina. These observations using flow velocity techniques to evaluate perturbations of collateral flow are the first physiologic demonstrations in patients of one of the unique hypothesized beneficial antiischemic mechanisms of intraaortic balloon pumping.

Original languageEnglish
Pages (from-to)1451-1455
Number of pages5
JournalThe American journal of cardiology
Volume71
Issue number16
DOIs
StatePublished - Jun 15 1993

Fingerprint

Dive into the research topics of 'Alterations of coronary collateral blood flow velocity during intraaortic balloon pumping'. Together they form a unique fingerprint.

Cite this