TY - JOUR
T1 - ALARA
T2 - Impact of practice quality improvement initiative on dose reduction in pediatric voiding cystourethrogram
AU - Jaju, Alok
AU - Shaw, Hillary L.
AU - Don, Steven
AU - Bowling, Rebecca Hulett
AU - Hildebolt, Charles F.
N1 - Publisher Copyright:
© American Roentgen Ray Society.
PY - 2015/10/1
Y1 - 2015/10/1
N2 - OBJECTIVE. This practice quality improvement study of pediatric voiding cystourethrogram (VCUG) investigated the adequacy of substituting last-image capture for digital-spot images and dose reduction when this substitution was implemented and determined correlations between dose-area products (DAPs), patient ages, and fluoroscopy times. MATERIALS AND METHODS. The study consisted of three phases: phase 1 documented baseline data and evaluated diagnostic accuracy between last-image capture and digital-spot images. Phase 2 documented the change in dose after substituting last-image capture for digital-spot images. Phase 3 measured doses 3 years later. Each phase-1 VCUG study was segregated into two image sets: last-image capture and digital-spot images. Three radiologists graded vesicoureteral reflux on each side using the international grading scale. Weighted kappa statistics assessed grading differences between image sets. Patient age, fluoroscopy time, and DAP were assessed with parametric and nonparametric statistics. RESULTS. Seventy-seven, 65, and 71 VCUGs were assessed for phases 1, 2, and 3, respectively. Weighted κ = 0.94-0.99 indicated nearly perfect agreement between last-image-capture and digital-spot-image interpretations. For phase 2, last-image capture was substituted for digital-spot images for early-filling and voiding images. DAP decreased for all three radiologists (p ≤ 0.01). Five of six (83%) correlations between DAP and age were higher than the correlations between DAP and fluoroscopy time. The dose remained significantly lower in phase 3. CONCLUSION. This project changed practice by substituting last-image capture for digital-spot images without affecting vesicoureteral reflux grading while reducing radiation exposure. Monitoring DAP is a better assessment of radiation exposure than is fluoroscopy time.
AB - OBJECTIVE. This practice quality improvement study of pediatric voiding cystourethrogram (VCUG) investigated the adequacy of substituting last-image capture for digital-spot images and dose reduction when this substitution was implemented and determined correlations between dose-area products (DAPs), patient ages, and fluoroscopy times. MATERIALS AND METHODS. The study consisted of three phases: phase 1 documented baseline data and evaluated diagnostic accuracy between last-image capture and digital-spot images. Phase 2 documented the change in dose after substituting last-image capture for digital-spot images. Phase 3 measured doses 3 years later. Each phase-1 VCUG study was segregated into two image sets: last-image capture and digital-spot images. Three radiologists graded vesicoureteral reflux on each side using the international grading scale. Weighted kappa statistics assessed grading differences between image sets. Patient age, fluoroscopy time, and DAP were assessed with parametric and nonparametric statistics. RESULTS. Seventy-seven, 65, and 71 VCUGs were assessed for phases 1, 2, and 3, respectively. Weighted κ = 0.94-0.99 indicated nearly perfect agreement between last-image-capture and digital-spot-image interpretations. For phase 2, last-image capture was substituted for digital-spot images for early-filling and voiding images. DAP decreased for all three radiologists (p ≤ 0.01). Five of six (83%) correlations between DAP and age were higher than the correlations between DAP and fluoroscopy time. The dose remained significantly lower in phase 3. CONCLUSION. This project changed practice by substituting last-image capture for digital-spot images without affecting vesicoureteral reflux grading while reducing radiation exposure. Monitoring DAP is a better assessment of radiation exposure than is fluoroscopy time.
KW - ALARA
KW - Digital-spot image
KW - Dose reduction
KW - Last-image capture
KW - Pediatric radiology
KW - Voiding cystourethrogram
UR - http://www.scopus.com/inward/record.url?scp=84943655427&partnerID=8YFLogxK
U2 - 10.2214/AJR.14.13492
DO - 10.2214/AJR.14.13492
M3 - Article
C2 - 26397340
AN - SCOPUS:84943655427
SN - 0361-803X
VL - 205
SP - 886
EP - 893
JO - American Journal of Roentgenology
JF - American Journal of Roentgenology
IS - 4
ER -