TY - JOUR
T1 - Advancing Quality Metrics for Durable Left Ventricular Assist Device Implant
T2 - Analysis of the Society of Thoracic Surgeons Intermacs Database
AU - Michigan Congestive Heart Failure Investigators
AU - Pienta, Michael J.
AU - Wu, Xiaoting
AU - Cascino, Thomas M.
AU - Brescia, Alexander A.
AU - Abou el Ela, Ashraf
AU - Zhang, Min
AU - McCullough, Jeffrey S.
AU - Shore, Supriya
AU - Aaronson, Keith D.
AU - Thompson, Michael P.
AU - Pagani, Francis D.
AU - Likosky, Donald S.
N1 - Publisher Copyright:
© 2022 The Society of Thoracic Surgeons
PY - 2022/5
Y1 - 2022/5
N2 - Background: Patients undergoing left ventricular assist device (LVAD) implantation are at risk for death and postoperative adverse outcomes. Interhospital variability and concordance of quality metrics were assessed using the Society of Thoracic Surgeons Interagency Registry for Mechanically Assisted Circulatory Support (Intermacs). Methods: A total of 22 173 patients underwent primary, durable LVAD implantation across 160 hospitals from 2012 to 2020, excluding hospitals performing <10 implant procedures. Observed and risk-adjusted operative mortality rates were calculated for each hospital. Outcomes included operative and 90-day mortality, a composite of adverse events (operative mortality, bleeding, stroke, device malfunction, renal dysfunction, respiratory failure), and secondarily failure to rescue. Rates are presented as median (interquartile range [IQR]). Hospital performance was evaluated using observed-to-expected (O/E) ratios for mortality and the composite outcome. Results: Interhospital variability existed in observed (median, 7.2% [IQR, 5.1%-9.6%]) mortality. The rates of adverse events varied across hospitals: major bleeding, 15.6% (IQR, 11.4%-22.4%); stroke, 3.1% (IQR, 1.6%-4.7%); device malfunction, 2.4% (IQR, 0.8%-3.7%); respiratory failure, 10.5% (IQR, 4.6%-15.7%); and renal dysfunction, 6.4% (IQR, 3.2%-9.6%). The O/E ratio for operative mortality varied from 0.0 to 6.1, whereas the O/E ratio for the composite outcome varied from 0.28 to 1.99. Hospital operative mortality O/E ratios were more closely correlated with the 90-day mortality O/E ratio (r = 0.74) than with the composite O/E ratio (r = 0.12). Conclusions: This study reported substantial interhospital variability in performance for hospitals implanting durable LVADs. These findings support the need to (1) report hospital-level performance (mortality, composite) and (2) undertake benchmarking activities to reduce unwarranted variability in outcomes.
AB - Background: Patients undergoing left ventricular assist device (LVAD) implantation are at risk for death and postoperative adverse outcomes. Interhospital variability and concordance of quality metrics were assessed using the Society of Thoracic Surgeons Interagency Registry for Mechanically Assisted Circulatory Support (Intermacs). Methods: A total of 22 173 patients underwent primary, durable LVAD implantation across 160 hospitals from 2012 to 2020, excluding hospitals performing <10 implant procedures. Observed and risk-adjusted operative mortality rates were calculated for each hospital. Outcomes included operative and 90-day mortality, a composite of adverse events (operative mortality, bleeding, stroke, device malfunction, renal dysfunction, respiratory failure), and secondarily failure to rescue. Rates are presented as median (interquartile range [IQR]). Hospital performance was evaluated using observed-to-expected (O/E) ratios for mortality and the composite outcome. Results: Interhospital variability existed in observed (median, 7.2% [IQR, 5.1%-9.6%]) mortality. The rates of adverse events varied across hospitals: major bleeding, 15.6% (IQR, 11.4%-22.4%); stroke, 3.1% (IQR, 1.6%-4.7%); device malfunction, 2.4% (IQR, 0.8%-3.7%); respiratory failure, 10.5% (IQR, 4.6%-15.7%); and renal dysfunction, 6.4% (IQR, 3.2%-9.6%). The O/E ratio for operative mortality varied from 0.0 to 6.1, whereas the O/E ratio for the composite outcome varied from 0.28 to 1.99. Hospital operative mortality O/E ratios were more closely correlated with the 90-day mortality O/E ratio (r = 0.74) than with the composite O/E ratio (r = 0.12). Conclusions: This study reported substantial interhospital variability in performance for hospitals implanting durable LVADs. These findings support the need to (1) report hospital-level performance (mortality, composite) and (2) undertake benchmarking activities to reduce unwarranted variability in outcomes.
UR - http://www.scopus.com/inward/record.url?scp=85126067660&partnerID=8YFLogxK
U2 - 10.1016/j.athoracsur.2022.01.031
DO - 10.1016/j.athoracsur.2022.01.031
M3 - Article
C2 - 35176258
AN - SCOPUS:85126067660
SN - 0003-4975
VL - 113
SP - 1544
EP - 1551
JO - Annals of Thoracic Surgery
JF - Annals of Thoracic Surgery
IS - 5
ER -