Accelerating Monte Carlo simulations of radiation therapy dose distributions using wavelet threshold de-noising

  • Joseph O. Deasy
  • , M. Victor Wickerhauser
  • , Mathieu Picard

Research output: Contribution to journalArticlepeer-review

34 Scopus citations

Abstract

The Monte Carlo dose calculation method works by simulating individual energetic photons or electrons as they traverse a digital representation of the patient anatomy. However, Monte Carlo results fluctuate until a large number of particles are simulated. We propose wavelet threshold de-noising as a postprocessing step to accelerate convergence of Monte Carlo dose calculations. A sampled rough function (such as Monte Carlo noise) gives wavelet transform coefficients which are more nearly equal in amplitude than those of a sampled smooth function. Wavelet hard-threshold de-noising sets to zero those wavelet coefficients which fall below a threshold; the image is then reconstructed. We implemented the computationally efficient 9,7-biorthogonal filters in the C language. Transform results were averaged over transform origin selections to reduce artifacts. A method for selecting best threshold values is described. The algorithm requires about 336 floating point arithmetic operations per dose grid point. We applied wavelet threshold de-noising to two two-dimensional dose distributions: a dose distribution generated by 10 MeV electrons incident on a water phantom with a step-heterogeneity, and a slice from a lung heterogeneity phantom. Dose distributions were simulated using the Integrated Tiger Series Monte Carlo code. We studied threshold selection, resulting dose image smoothness, and resulting dose image accuracy as a function of the number of source particles. For both phantoms, with a suitable value of the threshold parameter, voxel-to-voxel noise was suppressed with little introduction of bias. The roughness of wavelet de-noised dose distributions (according to a Laplacian metric) was nearly independent of the number of source electrons, though the accuracy of the de-noised dose image improved with increasing numbers of source electrons. We conclude that wavelet shrinkage de-noising is a promising method for effectively accelerating Monte Carlo dose calculations by factors of 2 or more.

Original languageEnglish
Pages (from-to)2366-2373
Number of pages8
JournalMedical physics
Volume29
Issue number10
DOIs
StatePublished - Oct 2002

Keywords

  • Monte Carlo
  • Wavelet threshold de-noising

Fingerprint

Dive into the research topics of 'Accelerating Monte Carlo simulations of radiation therapy dose distributions using wavelet threshold de-noising'. Together they form a unique fingerprint.

Cite this