TY - JOUR
T1 - A three-field monoisocentric inverse breast treatment planning technique without half-beam blocking
AU - Zhang, Tiezhi
AU - Dilworth, Joshua T.
AU - Marina, Ovidiu
AU - Chen, Peter
AU - Benedetti, Lisa
AU - Liu, Qiang
PY - 2015
Y1 - 2015
N2 - The purpose of this study was to introduce a three-field monoisocentric inverse treatment planning method without half-beam blocks for breast cancer radiation treatments. Three-field monoisocentric breast treatment planning with half-beam blocks limits the tangential field length to 20 cm. A dual-isocenter approach accommodates patients with larger breasts, but prolongs treatment time and may introduce dose uncertainty at the matching plane due to daily setup variations. We developed a novel monoisocentric, three-field treatment planning method without half-beam blocking. The new beam-matching method utilizes the full field size with a single isocenter. Furthermore, an open/IMRT hybrid inverse optimization method was employed to improve dose uniformity and coverage. Geometric beam matching was achieved by rotating the couch, collimator, and gantry together. Formulae for three-field geometric matching were derived and implemented in Pinnacle scripts. This monoisocentric technique can be used for patients with larger breast size. The new method has no constraints on the length of tangential fields. Compared with the dual-isocenter method, it can significantly reduce patient setup time anduncertainties.
AB - The purpose of this study was to introduce a three-field monoisocentric inverse treatment planning method without half-beam blocks for breast cancer radiation treatments. Three-field monoisocentric breast treatment planning with half-beam blocks limits the tangential field length to 20 cm. A dual-isocenter approach accommodates patients with larger breasts, but prolongs treatment time and may introduce dose uncertainty at the matching plane due to daily setup variations. We developed a novel monoisocentric, three-field treatment planning method without half-beam blocking. The new beam-matching method utilizes the full field size with a single isocenter. Furthermore, an open/IMRT hybrid inverse optimization method was employed to improve dose uniformity and coverage. Geometric beam matching was achieved by rotating the couch, collimator, and gantry together. Formulae for three-field geometric matching were derived and implemented in Pinnacle scripts. This monoisocentric technique can be used for patients with larger breast size. The new method has no constraints on the length of tangential fields. Compared with the dual-isocenter method, it can significantly reduce patient setup time anduncertainties.
KW - Breast cancer
KW - Monoisocentric technique
KW - Treatment planning
UR - http://www.scopus.com/inward/record.url?scp=84946903143&partnerID=8YFLogxK
U2 - 10.1120/jacmp.v16i5.5494
DO - 10.1120/jacmp.v16i5.5494
M3 - Article
C2 - 26699305
AN - SCOPUS:84946903143
SN - 1526-9914
VL - 16
SP - 246
EP - 258
JO - Journal of applied clinical medical physics
JF - Journal of applied clinical medical physics
IS - 5
ER -