A pressure based respiratory motion management system with biofeedback for MR-based radiotherapy

Benjamin Lewis, Robert Cadrain, Emma Fields, Siyong Kim, Taeho Kim

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Purpose: Motion must be accounted for with focal treatments such as liver directed stereotactic body radiotherapy otherwise there is a risk of marginal miss and/or increased toxicity to surrounding structure. There have been many proposed methods for motion management including respiratory gating, inhibition and tracking. The purpose of this study is to evaluate a pressure-based respiratory motion management system with biofeedback to the patient for MR-guided radiotherapy treatments. Methods: A respiratory motion management belt was modified in house to provide visual biofeedback of subject respiratory trace using pressure readings from an air bladder. Three groups participated in the study: Group I included two investigators who were imaged twice, with imaging sessions separated by one week, while wearing the motion management belt. Group II included four healthy volunteers, imaged using the belt for CINE and anatomical imaging. Group III included two cancer patients with liver lesions imaged while wearing the device, imaged pre-radiotherapy treatment, and post-treatment. During image acquisition, a display showed participants their respiratory traces and guidelines to indicate the desired respiratory amplitude. Results: The average peak-to-peak motion of the liver dome was decreased from 30.557.83 mm to 5.580.85 mm for free-breathing and utilizing a small window guiding box with visual guidance CINE image sets respectively in the investigator study. Volunteers and cancer patients were able to consistently manage their breath traces, including sequential breath holds, over the course of 30-60 min imaging sessions. Conclusions: The proposed motion management belt with visual biofeedback design is able to provide greatly reduced respiratory motion of the liver, and repeatable breath hold in MR simulation. The components used in the device also allow it to be in place during all steps of the radiotherapy planning process, including MR anatomical imaging, CT simulation, and treatment delivery due to the absence of high z or metallic material.

Original languageEnglish
Article number037003
JournalBiomedical Physics and Engineering Express
Volume5
Issue number3
DOIs
StatePublished - Apr 17 2019

Keywords

  • MRsafe motion management system
  • biofeedback
  • respiratory motion

Fingerprint

Dive into the research topics of 'A pressure based respiratory motion management system with biofeedback for MR-based radiotherapy'. Together they form a unique fingerprint.

Cite this