TY - JOUR
T1 - A multi-modal diagnostic model improves detection of cardiac amyloidosis among patients with diagnostic confirmation by cardiac biopsy
AU - Zhang, Kathleen W.
AU - Zhang, Ray
AU - Deych, Elena
AU - Stockerl-Goldstein, Keith E.
AU - Gorcsan, John
AU - Lenihan, Daniel J.
N1 - Publisher Copyright:
© 2020 Elsevier Inc.
PY - 2021/2
Y1 - 2021/2
N2 - Background: Timely recognition of cardiac amyloidosis is clinically important, but the diagnosis is frequently delayed. Objectives: We sought to identify a multi-modality approach with the highest diagnostic accuracy in patients evaluated by cardiac biopsy, the diagnostic gold standard. Methods: Consecutive patients (N = 242) who underwent cardiac biopsy for suspected amyloidosis within an 18-year period were retrospectively identified. Cardiac biomarker, ECG, and echocardiography results were examined for correlation with biopsy-proven disease. A prediction model for cardiac amyloidosis was derived using multivariable logistic regression. Results: The overall cohort was characterized by elevated BNP (median 727 ng/mL), increased left ventricular wall thickness (IWT; median 1.7 cm), and reduced voltage-to-mass ratio (median 0.06 mm/[g/m2]). One hundred and thirteen patients (46%) had either light chain (n = 53) or transthyretin (n = 60) amyloidosis by cardiac biopsy. A prediction model including age, relative wall thickness, left atrial pressure by E/e’, and low limb lead voltage (<0.5 mV) showed good discrimination for cardiac amyloidosis with an optimism-corrected c-index of 0.87 (95% CI 0.83-0.92). The diagnostic accuracy of this model (79% sensitivity, 84% specificity) surpassed that of traditional screening parameters, such as IWT in the absence of left ventricular hypertrophy on ECG (98% sensitivity, 20% specificity) and IWT with low limb lead voltage (49% sensitivity, 91% specificity). Conclusion: Among patients with an advanced infiltrative cardiomyopathy phenotype, traditional biomarker, ECG, and echocardiography-based screening tests have limited individual diagnostic utility for cardiac amyloidosis. A prediction algorithm including age, relative wall thickness, E/e’, and low limb lead voltage improves the detection of cardiac biopsy-proven disease.
AB - Background: Timely recognition of cardiac amyloidosis is clinically important, but the diagnosis is frequently delayed. Objectives: We sought to identify a multi-modality approach with the highest diagnostic accuracy in patients evaluated by cardiac biopsy, the diagnostic gold standard. Methods: Consecutive patients (N = 242) who underwent cardiac biopsy for suspected amyloidosis within an 18-year period were retrospectively identified. Cardiac biomarker, ECG, and echocardiography results were examined for correlation with biopsy-proven disease. A prediction model for cardiac amyloidosis was derived using multivariable logistic regression. Results: The overall cohort was characterized by elevated BNP (median 727 ng/mL), increased left ventricular wall thickness (IWT; median 1.7 cm), and reduced voltage-to-mass ratio (median 0.06 mm/[g/m2]). One hundred and thirteen patients (46%) had either light chain (n = 53) or transthyretin (n = 60) amyloidosis by cardiac biopsy. A prediction model including age, relative wall thickness, left atrial pressure by E/e’, and low limb lead voltage (<0.5 mV) showed good discrimination for cardiac amyloidosis with an optimism-corrected c-index of 0.87 (95% CI 0.83-0.92). The diagnostic accuracy of this model (79% sensitivity, 84% specificity) surpassed that of traditional screening parameters, such as IWT in the absence of left ventricular hypertrophy on ECG (98% sensitivity, 20% specificity) and IWT with low limb lead voltage (49% sensitivity, 91% specificity). Conclusion: Among patients with an advanced infiltrative cardiomyopathy phenotype, traditional biomarker, ECG, and echocardiography-based screening tests have limited individual diagnostic utility for cardiac amyloidosis. A prediction algorithm including age, relative wall thickness, E/e’, and low limb lead voltage improves the detection of cardiac biopsy-proven disease.
UR - http://www.scopus.com/inward/record.url?scp=85096848553&partnerID=8YFLogxK
U2 - 10.1016/j.ahj.2020.11.006
DO - 10.1016/j.ahj.2020.11.006
M3 - Article
C2 - 33212046
AN - SCOPUS:85096848553
SN - 0002-8703
VL - 232
SP - 137
EP - 145
JO - American heart journal
JF - American heart journal
ER -