T1 - A moving target
T2 - Image guidance for stereotactic body radiation therapy for early-stage non-small cell lung cancer
AU - Corradetti, Michael N.
AU - Mitra, Nandita
AU - Bonner Millar, Lara P.
AU - Byun, John
AU - Wan, Fei
AU - Apisarnthanarax, Smith
AU - Christodouleas, John
AU - Anderson, Nathan
AU - Simone, Charles B.
AU - Teo, Boon Keng
AU - Rengan, Ramesh
PY - 2013/10
Y1 - 2013/10
N2 - Purpose: Precise patient positioning is critical due to the large fractional doses and small treatment margins employed for thoracic stereotactic body radiation therapy (SBRT). The goals of this study were to evaluate the following: (1) the accuracy of kilovoltage x-ray (kV x-ray) matching to bony anatomy for pretreatment positioning; (2) the magnitude of intrafraction tumor motion; and (3) whether treatment or patient characteristics correlate with intrafraction motion. Methods and Materials: Eighty-seven patients with lung cancer were treated with SBRT. Patients were positioned with orthogonal kV x-rays matched to bony anatomy followed by cone-beam computed tomography (CBCT), with matching of the CBCT-visualized tumor to the internal gross target volume obtained from a 4-dimensional CT simulation data set. Patients underwent a posttreatment CBCT to assess the magnitude of intrafraction motion. Results: The mean CBCT-based shifts after initial patient positioning using kV x-rays were 2.2 mm in the vertical axis, 1.8 mm in the longitudinal axis, and 1.6 mm in the lateral axis (n = 335). The percentage of shifts greater than 3 mm and 5 mm represented 39% and 17%, respectively, of all fractions delivered. The mean CBCT-based shifts after treatment were 1.6 mm vertically, 1.5 mm longitudinally, and 1.1 mm laterally (n = 343). Twenty-seven percent and 10% of shifts were greater than 3 mm and 5 mm, respectively. Univariate and multivariable analysis demonstrated a significant association between intrafraction motion with weight and pulmonary function. Conclusions: Kilovoltage x-ray matching to bony anatomy is inadequate for accurate positioning when a conventional 3-5 mm margin is employed prior to lung SBRT. Given the treatment techniques used in this study, CBCT image guidance with a 5-mm planning target volume margin is recommended. Further work is required to find determinants of interfraction and intrafraction motion that may help guide the individualized application of planning target volume margins.
AB - Purpose: Precise patient positioning is critical due to the large fractional doses and small treatment margins employed for thoracic stereotactic body radiation therapy (SBRT). The goals of this study were to evaluate the following: (1) the accuracy of kilovoltage x-ray (kV x-ray) matching to bony anatomy for pretreatment positioning; (2) the magnitude of intrafraction tumor motion; and (3) whether treatment or patient characteristics correlate with intrafraction motion. Methods and Materials: Eighty-seven patients with lung cancer were treated with SBRT. Patients were positioned with orthogonal kV x-rays matched to bony anatomy followed by cone-beam computed tomography (CBCT), with matching of the CBCT-visualized tumor to the internal gross target volume obtained from a 4-dimensional CT simulation data set. Patients underwent a posttreatment CBCT to assess the magnitude of intrafraction motion. Results: The mean CBCT-based shifts after initial patient positioning using kV x-rays were 2.2 mm in the vertical axis, 1.8 mm in the longitudinal axis, and 1.6 mm in the lateral axis (n = 335). The percentage of shifts greater than 3 mm and 5 mm represented 39% and 17%, respectively, of all fractions delivered. The mean CBCT-based shifts after treatment were 1.6 mm vertically, 1.5 mm longitudinally, and 1.1 mm laterally (n = 343). Twenty-seven percent and 10% of shifts were greater than 3 mm and 5 mm, respectively. Univariate and multivariable analysis demonstrated a significant association between intrafraction motion with weight and pulmonary function. Conclusions: Kilovoltage x-ray matching to bony anatomy is inadequate for accurate positioning when a conventional 3-5 mm margin is employed prior to lung SBRT. Given the treatment techniques used in this study, CBCT image guidance with a 5-mm planning target volume margin is recommended. Further work is required to find determinants of interfraction and intrafraction motion that may help guide the individualized application of planning target volume margins.
UR - http://www.scopus.com/inward/record.url?scp=84884349915&partnerID=8YFLogxK
U2 - 10.1016/j.prro.2012.10.005
DO - 10.1016/j.prro.2012.10.005
M3 - Article
C2 - 24674403
AN - SCOPUS:84884349915
SN - 1879-8500
VL - 3
SP - 307
EP - 315
JO - Practical Radiation Oncology
JF - Practical Radiation Oncology
IS - 4
ER -