Abstract

Nerve regeneration across a vascularized pseudosheath and a sural nerve graft was compared in a primate model using histologic and electrophysiologic parameters for regeneration. At 12 months, regeneration was noted across both the vascularized pseudosheath and the sural nerve graft. Although histologic and electrophysiologic properties of the regenerated nerve were significantly different from the normal ulnar nerve, the quality of regeneration noted between experimental groups was similar.

Original languageEnglish
Pages (from-to)935-942
Number of pages8
JournalJournal of Hand Surgery
Volume13
Issue number6
DOIs
StatePublished - Nov 1988

Fingerprint

Dive into the research topics of 'A comparison of nerve regeneration across a sural nerve graft and a vascularized pseudosheath'. Together they form a unique fingerprint.