TY - JOUR
T1 - A comparison of biphasic and monophasic shocks for external defibrillation
AU - Higgins, Steven L.
AU - Herre, John M.
AU - Epstein, Andrew E.
AU - Greer, G. Stephen
AU - Friedman, Peter L.
AU - Gleva, Marye L.
AU - Porterfield, James G.
AU - Chapman, Fred W.
AU - Finkel, Elizabeth S.
AU - Schmitt, Paul W.
AU - Nova, Richard C.
AU - Greene, H. Leon
N1 - Funding Information:
Supported by a grant from Physio-Control Corporation.
PY - 2000
Y1 - 2000
N2 - Background and Objective. The ability of a shock to defibrillate the heart depends on its waveform and energy. Past studies of biphasic truncated exponential (BTE) shocks for external defibrillation focused on low energy levels. This prospective, randomized, double-blind clinical trial compared the first-shock efficacies of 200-joule (J) BTE, 130-J BTE, and 200-J monophasic damped sine wave shocks. Methods. Ventricular fibrillation (VF) was induced in 115 patients during evaluation of implantable cardioverter-defibrillator function and 39 patients during electrophysiologic evaluation of ventricular arrhythmias. After 19 ± 10 seconds of VF, a randomized transthoracic shock was administered. Mean first-shock success rates of the three groups were compared using a 'Tukey-like' statistical test, adjusting for multiple comparisons. Blood pressures and arterial oxygen saturations were measured before VF induction and 30, 90, and 150 seconds after successful defibrillation. Results. First-shock success rates were 61/68 (90%) for 200-J monophasic, 39/39 (100%) for 200-J biphasic, and 39/47 (83%) for 130-J biphasic shocks. The 200-J biphasic shocks were simultaneously superior in first-shock efficacy to both 200-J monophasic and 130-J biphasic shocks (experimentwise error rate, α < 0.01). There was no significant difference between the efficacies of 200-J monophasic and 130-J biphasic shocks, nor was there any significant difference between the three groups in hemodynamic parameters after successful shocks. Conclusions. Biphasic shocks of 200 J provide better first-shock defibrillation efficacy for short-duration VF than 200-J monophasic and 130-J biphasic shocks and thus may allow earlier termination of VF in cardiac arrest patients.
AB - Background and Objective. The ability of a shock to defibrillate the heart depends on its waveform and energy. Past studies of biphasic truncated exponential (BTE) shocks for external defibrillation focused on low energy levels. This prospective, randomized, double-blind clinical trial compared the first-shock efficacies of 200-joule (J) BTE, 130-J BTE, and 200-J monophasic damped sine wave shocks. Methods. Ventricular fibrillation (VF) was induced in 115 patients during evaluation of implantable cardioverter-defibrillator function and 39 patients during electrophysiologic evaluation of ventricular arrhythmias. After 19 ± 10 seconds of VF, a randomized transthoracic shock was administered. Mean first-shock success rates of the three groups were compared using a 'Tukey-like' statistical test, adjusting for multiple comparisons. Blood pressures and arterial oxygen saturations were measured before VF induction and 30, 90, and 150 seconds after successful defibrillation. Results. First-shock success rates were 61/68 (90%) for 200-J monophasic, 39/39 (100%) for 200-J biphasic, and 39/47 (83%) for 130-J biphasic shocks. The 200-J biphasic shocks were simultaneously superior in first-shock efficacy to both 200-J monophasic and 130-J biphasic shocks (experimentwise error rate, α < 0.01). There was no significant difference between the efficacies of 200-J monophasic and 130-J biphasic shocks, nor was there any significant difference between the three groups in hemodynamic parameters after successful shocks. Conclusions. Biphasic shocks of 200 J provide better first-shock defibrillation efficacy for short-duration VF than 200-J monophasic and 130-J biphasic shocks and thus may allow earlier termination of VF in cardiac arrest patients.
KW - Defibrillation
KW - External defibrillators
KW - Ventricular fibrillation
UR - http://www.scopus.com/inward/record.url?scp=0033790640&partnerID=8YFLogxK
U2 - 10.1080/10903120090941001
DO - 10.1080/10903120090941001
M3 - Article
C2 - 11045408
AN - SCOPUS:0033790640
SN - 1090-3127
VL - 4
SP - 305
EP - 313
JO - Prehospital Emergency Care
JF - Prehospital Emergency Care
IS - 4
ER -